Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/8130
metadata.dc.type: Artigo de Periódico
Título : Doehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extraction
Otros títulos : Analytical and Bioanalytical Chemistry
Autor : Bezerra, Marcos de Almeida
Conceição, André L. B.
Ferreira, Sergio Luis Costa
metadata.dc.creator: Bezerra, Marcos de Almeida
Conceição, André L. B.
Ferreira, Sergio Luis Costa
Resumen : This paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by flame atomic absorption spectrometry (FAAS).It is based on cloud-point extraction of nickel(II) ions as 2-(5-bromo-2-pyridylazo)-5 diethilaminophenol (Br-PADAP) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The optimisation step was performed using a four-variable Doehlert design, involving the factors centrifugation time (CT) of system after addition of surfactant, solution pH, methanol volume (MV) added at micellar phase, and buffer concentration (BC). The analytical response used was absorbance, after volume correction. Using the established experimental conditions in the optimisation step the procedure enables nickel determination with a detection limit (3δ/S) of 0.2 μgL–1, quantification limit (10δ/S) of 0.7 μgL–1, and precision, calculated as relative standard deviation (RSD) of 4.7 (n=8) and 3.5% (n=8) for nickel concentration of 1 and 5 μgL–1, respectively. The preconcentration factor, determined from the ratio of the slopes of the analytical curves with and without preconcentration, is 74. The recovery achieved for nickel determination in the presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The robustness was checked by using saturated fractional factorial designs, centred on the established experimental conditions in the optimisation step. The results of these tests demonstrated that the variables centrifugation time and buffer concentration are robust for modification by 10% and that solution pH and methanol volume are robust for 5%. Accuracy was evaluated by using the certified material reference SLEW-3 estuarine water for trace metals. The procedure was used for determination of nickel in saline effluents from oil refinery samples. Recovery results (95–104%) indicate that the procedure has satisfactory accuracy for nickel determination in these samples.
Palabras clave : Oil-refinery waste
Saline effluents
Doehlert matrix
Flame atomic absorption spectrometry
Cloud-point extraction
Nickel
URI : http://www.repositorio.ufba.br/ri/handle/ri/8130
Fecha de publicación : 2004
Aparece en las colecciones: Artigo Publicado em Periódico (Química)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
art%3A10.1007%2Fs00216-003-2349-4.pdf
  Restricted Access
249,38 kBAdobe PDFVisualizar/Abrir  Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.