Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/8130
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBezerra, Marcos de Almeida-
dc.contributor.authorConceição, André L. B.-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorBezerra, Marcos de Almeida-
dc.creatorConceição, André L. B.-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2013-01-24T19:48:59Z-
dc.date.issued2004-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/8130-
dc.descriptionTexto completo: acesso restrito. p. 798-803pt_BR
dc.description.abstractThis paper proposes a preconcentration procedure for determination of nickel in saline aqueous waste samples by flame atomic absorption spectrometry (FAAS).It is based on cloud-point extraction of nickel(II) ions as 2-(5-bromo-2-pyridylazo)-5 diethilaminophenol (Br-PADAP) complexes using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The optimisation step was performed using a four-variable Doehlert design, involving the factors centrifugation time (CT) of system after addition of surfactant, solution pH, methanol volume (MV) added at micellar phase, and buffer concentration (BC). The analytical response used was absorbance, after volume correction. Using the established experimental conditions in the optimisation step the procedure enables nickel determination with a detection limit (3δ/S) of 0.2 μgL–1, quantification limit (10δ/S) of 0.7 μgL–1, and precision, calculated as relative standard deviation (RSD) of 4.7 (n=8) and 3.5% (n=8) for nickel concentration of 1 and 5 μgL–1, respectively. The preconcentration factor, determined from the ratio of the slopes of the analytical curves with and without preconcentration, is 74. The recovery achieved for nickel determination in the presence of several cations demonstrated that this procedure could be applied for analysis of water samples. The robustness was checked by using saturated fractional factorial designs, centred on the established experimental conditions in the optimisation step. The results of these tests demonstrated that the variables centrifugation time and buffer concentration are robust for modification by 10% and that solution pH and methanol volume are robust for 5%. Accuracy was evaluated by using the certified material reference SLEW-3 estuarine water for trace metals. The procedure was used for determination of nickel in saline effluents from oil refinery samples. Recovery results (95–104%) indicate that the procedure has satisfactory accuracy for nickel determination in these samples.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://link.springer.com/article/10.1007%2Fs00216-003-2349-4pt_BR
dc.subjectOil-refinery wastept_BR
dc.subjectSaline effluentspt_BR
dc.subjectDoehlert matrixpt_BR
dc.subjectFlame atomic absorption spectrometrypt_BR
dc.subjectCloud-point extractionpt_BR
dc.subjectNickelpt_BR
dc.titleDoehlert matrix for optimisation of procedure for determination of nickel in saline oil-refinery effluents by use of flame atomic absorption spectrometry after preconcentration by cloud-point extractionpt_BR
dc.title.alternativeAnalytical and Bioanalytical Chemistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 378, n. 3pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
art%3A10.1007%2Fs00216-003-2349-4.pdf
  Restricted Access
249,38 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.