Título : Copper determination in natural water samples by using FAAS after preconcentration onto amberlite XAD-2 loaded with calmagite
Otros títulos : Talanta
Autor : Ferreira, Sergio Luis Costa
Ferreira, Janeide R.
Dantas, Alailson Falcão
Lemos, Valfredo Azevedo
Araújo, Neyla Margarida Lopo de
Costa, Antonio Celso Spinola
metadata.dc.creator: Ferreira, Sergio Luis Costa
Ferreira, Janeide R.
Dantas, Alailson Falcão
Lemos, Valfredo Azevedo
Araújo, Neyla Margarida Lopo de
Costa, Antonio Celso Spinola
Resumen : A procedure for separation and preconcentration of trace amounts of copper in natural water samples, has been proposed. It is based on the adsorption of copper(II) ions onto a column of Amberlite XAD-2 resin loaded with calmagite reagent. This way amounts of copper within the range from 0.0125 to 25.0 μg, in a sample volume of 25 to 250 ml, and pH from 3.7 to 10.0 was concentrated as calmagite complex in a column of 0.50 g of Amberlite XAD-2 resin. Copper (II) ion was desorpted by using 5.0 ml of 2 mol l−1 hydrochloric acid. Detection and determination limits of the proposed procedure for 250 ml sample volume were 0.15 and 0.50 μg l−1, respectively. Selectivity test showed that (in the indicated concentration), calcium(II) (500 mg l−1), magnesium(II) (500 mg l−1), strontium(II) (50 mg l−1), iron(III) (10 mg l−1), nickel(II) (10 mg l−1), cobalt(II) (10 mg l−1), cadmium(II) (10 mg l−1) and lead(II) (10 mg l−1) did not interfere in copper determination by this procedure. Precision of the method, evaluated as the relative standard deviation by analyzing a series of seven replicates, was 2.42% for a copper mass of 1.0 μg in a sample volume of 100 ml. The accuracy of the proposed procedure was evaluated by means of copper determination in reference biological samples. The achieved results were in good agreement with certified values. The extractor system had a sorption capacity of 1.59 μmol of copper per gram of resin loaded with calmagite. The proposed procedure was applied for copper determination by FAAS in natural water samples. Samples were collected from different places of Salvador city, Bahia, Brazil. The achieved recovery, measured by the standard addition technique, showed that the proposed procedure had good accuracy. A good enrichment factor (50×) and simplicity are the main advantages in this analytical procedure.
Palabras clave : Copper determination
Natural water samples
FAAS
Calmagite
URI : http://www.repositorio.ufba.br/ri/handle/ri/7888
Fecha de publicación : 2000
Aparece en las colecciones: Artigo Publicado em Periódico (Química)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Ferreira.pdf
  Restricted Access
79,71 kBAdobe PDFVisualizar/Abrir  Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.