Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/15475
Tipo: Artigo de Periódico
Título: Development of an Analytical Method Based in the Slurry Sampling for Iron Determination in Fortified Milk Powder by HR-CS FAAS
Título(s) alternativo(s): Food Analytical Methods
Autor(es): Brandão, Geovani Cardoso
Gomes, Dalita Pedrosa
Matos, Geraldo Domingues
Autor(es): Brandão, Geovani Cardoso
Gomes, Dalita Pedrosa
Matos, Geraldo Domingues
Abstract: The use of slurry sampling as the procedure for sample preparation provides simplicity, speed, and low consumption of reagents in analytical methods. In this paper, a method based on slurry sampling for the determination of iron in samples of fortified milk powder by high-resolution continuum source flame atomic absorption spectrometry was developed. Multivariate design techniques were applied for the optimization of experimental conditions of the method for a sample mass of 100 mg, final volume of slurry of 10 mL, and using the absorbance signal as response. Initially, a two-level full factorial design was used for the preliminary evaluation of the variables involved in slurry preparation: concentration hydrochloric acid, Triton X-100 concentration, and sonication time. Then, the Doehlert matrix was applied for the determination of the critical conditions: 2.5 mol L−1 hydrochloric acid and sonication time of 20 min. External calibration technique with aqueous standard was used for the quantification of iron. This way, the method allowed iron determination with limits of detection and quantification of 0.9 and 3.0 μg g−1, respectively. The precision expressed as the relative standard deviation was evaluated under repeatability and reproducibility conditions, being 3.2% and 4.0%, respectively. Addition/recovery test was used for assessing the accuracy of the method, and the recovery values achieved were in the range of 90–110%. The method was applied for iron determination in eight samples of fortified milk powder, and the obtained concentrations varied from 95.4 to 295.6 μg g−1. The results were compared with those obtained after acid digestion, and no significant difference was observed applying t test at the 95% confidence level.
Palavras-chave: Slurry sampling
Iron determination
Fortified milk powder
Multivariate optimization
HR-CS FAAS
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/15475
Data do documento: 2012
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.