Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/5930
metadata.dc.type: Artigo de Periódico
Título : Hardening of a dual-cure resin cement using QTH and LED curing units
Otros títulos : Journal of Applied Oral Science
Autor : Santos, Maria Jacinta Moraes Coelho
Passos, Sheila Pestana
Encarnação, Monalisa Olga Lessa da
Santos Junior, Gildo Coelho
Bottino, Marco Antonio
metadata.dc.creator: Santos, Maria Jacinta Moraes Coelho
Passos, Sheila Pestana
Encarnação, Monalisa Olga Lessa da
Santos Junior, Gildo Coelho
Bottino, Marco Antonio
Resumen : OBJECTIVE: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light-emitting diode (LED) or quartz tungsten halogen (QTH) light source. MATERIAL AND METHODS: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. RESULTS: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. CONCLUSION: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.
Palabras clave : Hardness
Cure
Resin cements
Editorial : Scielo
URI : http://www.repositorio.ufba.br/ri/handle/ri/5930
Fecha de publicación : abr-2010
Aparece en las colecciones: Artigo Publicado em Periódico (Faculdade de Odontologia)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
(29)a03v18n2.pdf59,57 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.