Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/41508
Tipo: Dissertação
Título: Análise das propriedades psicométricas de um dispositivo portátil impresso em 3D desenvolvido para avaliar a força muscular respiratória
Título(s) alternativo(s): Analysis of the psychometric properties of a portable 3D printed device developed to assess respiratory muscle strength
Autor(es): Scaldaferri, Giselle Bárbara de Almeida
Primeiro Orientador: Ferraz, Daniel Dominguez
metadata.dc.contributor.advisor-co1: Oliveira Neto, João Soares de
metadata.dc.contributor.referee1: Ferraz, Daniel Dominguez
metadata.dc.contributor.referee2: Miranda, José Garcia Vivas
metadata.dc.contributor.referee3: Fonseca, Erika Pedreira da
metadata.dc.contributor.referee4: Oliveira Neto, João Soares de
Resumo: Introdução: A avaliação da força muscular respiratória fornece dados que podem ser utilizados tanto no diagnóstico de doenças e comprometimento da função respiratória, como na progressão da carga do treinamento muscular respiratório. Atualmente, não existem aparelhos com as funções de mensurar as pressões respiratórias máximas e realizar o treinamento muscular respiratório, sendo este o objetivo final dessa produção. Objetivo: Analisar as propriedades psicométricas de um dispositivo portátil impresso em 3D (DPI-3D) desenvolvido para avaliar a força muscular respiratória. Método: Trata-se de um estudo metodológico com o objetivo de avaliar a validade de conteúdo, a validade convergente e a confiabilidade de um DPI-3D. Para a validação de conteúdo, foi realizado um estudo com 6 participantes especialistas na área de Fisioterapia cardiorrespiratória. Os participantes responderam a um questionário semi-estruturado para avaliação do dispositivo, cuja concordância nas respostas alcançou mais de 70%. Posteriormente, foi realizada a fase longitudinal e prospectiva, com 10 idosas, para verificar a validade convergente e a confiabilidade do DPI-3D. Foi mensurada a pressão inspiratória máxima (PImáx) e a pressão expiratória máxima (PEmáx) das participantes, usando o manovacuômetro (aparelho padrão ouro) e o DPI-3D, denominado de SmartBreathe (SB), em dois momentos distintos. Resultados: O índice de validade de conteúdo total na 2ª rodada de avaliações do SB foi adequado e superior ao da 1ª rodada, com pontuação de 0.90. Também foi encontrado um coeficiente de correlação intraclasse estatisticamente significativo e superior a 0.75 ao comparar valores, da 1ª e 2ª avaliação do SB e do manovacuômetro, intra e inter-aparelhos. Conclusão: O SB se mostrou como um instrumento que reflete adequadamente o construto que está sendo medido. Além disso, as medições da PImáx e PEmáx realizadas no SB demonstraram excelente confiabilidade e fortes correlações com as medições realizadas com o padrão-ouro.
Abstract: Introduction: The assessment of respiratory muscle strength provides data that can be used both in the diagnosis of diseases and impairment of respiratory function, as well as in the progression of respiratory muscle training load. Currently, there are no devices with the functions of measuring maximum respiratory pressures and performing respiratory muscle training, which is the ultimate goal of this production. Objective: To analyze the psychometric properties of a portable 3D printed device (DPI-3D) developed to assess respiratory muscle strength. Method: This is a methodological study aimed at evaluating the content validity, convergent validity and reliability of a 3D-DPI. For content validation, a study was carried out with 6 participants who were experts in the area of cardiorespiratory physiotherapy. The participants answered a semi-structured questionnaire to evaluate the device, whose agreement in the answers reached more than 70%. Subsequently, the longitudinal and prospective phase was carried out, with 10 elderly women, to verify the convergent validity and reliability of the 3D-DPI. The maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP) of the participants were measured, using the manovacuometer (gold standard device) and the 3D-DPI, called SmartBreathe (SB), at two different times. Results: The total content validity index in the 2nd round of SB assessments was adequate and higher than that of the 1st round, with a score of 0.90. A statistically significant intraclass correlation coefficient higher than 0.75 was also found when comparing values from the 1st and 2nd SB and manovacuometer assessments, intra and inter-devices.. Conclusion: The SB proved to be an instrument that adequately reflects the construct being measured. Furthermore, the MIP and MEP measurements performed with the SB demonstrated excellent reliability and strong correlations with measurements performed with the gold standard.
Palavras-chave: Pressões Respiratórias Máximas
Músculos Respiratórios
Psicometria
Estudo de Validação
Desenvolvimento Tecnológico
CNPq: CNPQ::CIENCIAS DA SAUDE
CNPQ::CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL
Idioma: por
País: Brasil
Editora / Evento / Instituição: Universidade Federal da Bahia
Sigla da Instituição: UFBA
metadata.dc.publisher.department: Instituto Multidisciplinar de Reabilitação e Saúde (IMRS)
metadata.dc.publisher.program: Programa de Pós Graduação em Ciências da Reabilitação (PPGREAB)
Citação: SCALDAFERRI, Giselle Bárbara de Almeida. Análise das propriedades psicométricas de um dispositivo portátil impresso em 3D desenvolvido para avaliar a força muscular respiratória. Orientador: Daniel Dominguez Ferraz; Coorientador: João Soares de Oliveira Neto. 2024. 74 f. Dissertação (Mestrado em Ciências da Reabilitação) - Instituto Multidisciplinar de Reabilitação e Saúde, Universidade Federal da Bahia, Salvador, 2024.
Tipo de Acesso: Acesso Restrito/Embargado
URI: https://repositorio.ufba.br/handle/ri/41508
Data do documento: 16-Dez-2024
Aparece nas coleções:Dissertação (PPGREAB)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Giselle Bárbara de Almeida Scaldaferri TCC - dissertação versão final.pdf
  Until 2026-02-21
3,34 MBAdobe PDFVisualizar/Abrir Solicitar uma cópia
ata_de_defesa_de_dissertacao_Giselle Bárbara de Almeida Scaldaferri.pdf521,93 kBAdobe PDFVisualizar/Abrir
Termo de autorização para disponibilização de documentos no repositório institucional.pdf494,51 kBAdobe PDFVisualizar/Abrir
Mostrar registro completo do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.