Please use this identifier to cite or link to this item: https://repositorio.ufba.br/handle/ri/37912
Full metadata record
DC FieldValueLanguage
dc.creatorSouza, Cheilane Tavares-
dc.date.accessioned2023-09-29T09:06:04Z-
dc.date.available2023-09-29T09:06:04Z-
dc.date.issued2021-10-08-
dc.identifier.citationSOUZA, Cheilane Tavares de. Desenvolvimento de sistemas analíticos portáteis espectrofotométrico e fluorimétrico baseados em imagem digital. 2021. 108 f. Tese (Doutorado em Química) - Instituto de Química, Universidade Federal da Bahia, Salvador (Bahia), 2021.pt_BR
dc.identifier.urihttps://repositorio.ufba.br/handle/ri/37912-
dc.description.abstractIn the present work, portable systems for analytical determinations based on digital image analysis were developed and applied. The first chapter presents general information about the use of color information, from digital images, to build the analytical signal. The second chapter presents the development of a portable spectrophotometric system that employs a 3D device to attach a webcam as a detection system; the system is fully powered by a computer's USB ports and makes use of an LED as a radiation source, powered by an adjustable voltage source. The preliminary performance of the system was evaluated in iron (II) and hypochlorite determinations, using color data from the RGB space and the effective absorbance mathematical processing. The system showed good analytical performance placing the LED on top of the cuvette and radiation source with maximum intensity. The third chapter presents the application of the spectrophotometric system developed in the determination of the external marker, titanium dioxide, in bovine feces. The method presented detection and quantification limits of 0.57 and 0.85 mg 100g-1, respectively; linear working range from 0.85 to 10 mg 100g-1 and accuracy, expressed in terms of RSD, of 1.86%. The accuracy of the method was verified by comparing the results found by the proposed method with the reference spectrophotometric method and there was no significant difference. The fourth chapter presents a portable fluorimetric system, which makes use of a monochromatic LED in the excitation stage, to determine quinine in commercial samples of tonic water. The system presented satisfactory performance, with a linear working range from 0.99 to 10 mg L-1, correlation coefficient equal to 0.998 and average precision (RSD) of 1.14%. The samples had quinine contents from 47.8 to 66.7 mg L-1, within the standards established by current legislation. The developed systems showed good performance, proving to be promising, alternatives to the reference methods, for analytical determinations based on digital image analysispt_BR
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPESpt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Bahiapt_BR
dc.subjectAnálise de imagem digitalpt_BR
dc.subjectRGBpt_BR
dc.subjectProcessamentos matemáticospt_BR
dc.subjectSistemas portáteispt_BR
dc.subjectDispositivos 3Dpt_BR
dc.subjectDióxido de titâniopt_BR
dc.subjectFezes bovinas e quinina.pt_BR
dc.subject.otherDigital image analysispt_BR
dc.subject.otherRGBpt_BR
dc.subject.otherMath processingpt_BR
dc.subject.otherHandheld systemspt_BR
dc.subject.other3D devicespt_BR
dc.subject.otherTitanium dioxidept_BR
dc.subject.otherBovine feces and quininept_BR
dc.titleDesenvolvimento de sistemas analíticos portáteis espectrofotométrico e fluorimétrico baseados em imagem digital.pt_BR
dc.title.alternativeDevelopment of portable analytical systems spectrophotometric and fluorimetric based on digital imaging.pt_BR
dc.typeTesept_BR
dc.publisher.programPrograma de Pós-Graduação em Química pt_BR
dc.publisher.initialsUFBApt_BR
dc.publisher.countryBrasilpt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICApt_BR
dc.contributor.advisor1Ferreira, Sergio Luís Costa-
dc.contributor.advisor1IDhttps://orcid.org/0000-0001-7738-045Xpt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/9198426685541534pt_BR
dc.contributor.referee1Ferreira, Sergio Luís Costa-
dc.contributor.referee1IDhttps://orcid.org/0000-0001-7738-045Xpt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/9198426685541534pt_BR
dc.contributor.referee2Pereira Junior , João Batista-
dc.contributor.referee2IDhttps://orcid.org/0000-0002-7851-8235pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/8067391313688681pt_BR
dc.contributor.referee3Ribeiro, Anderson Schwingel-
dc.contributor.referee3IDhttps://orcid.org/0000-0001-9819-615Xpt_BR
dc.contributor.referee3Latteshttp://lattes.cnpq.br/2041807074893443pt_BR
dc.contributor.referee4Machado, Maria Elisabete-
dc.contributor.referee4IDhttps://orcid.org/0000-0001-8289-4842pt_BR
dc.contributor.referee4Latteshttp://lattes.cnpq.br/4472056042009533pt_BR
dc.contributor.referee5Santos , Ivanice Ferreira dos-
dc.contributor.referee5IDhttps://orcid.org/0000-0002-0390-2005pt_BR
dc.contributor.referee5Latteshttp://lattes.cnpq.br/3393553125456224pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/1184164764260365pt_BR
dc.description.resumoNo presente trabalho foram desenvolvidos e aplicados sistemas portáteis para determinações analíticas baseadas em análise de imagem digital. O primeiro capítulo apresenta informações gerais sobre a utilização de dados de cor, a partir de imagens digitais, para construção do sinal analítico. O segundo capítulo apresenta o desenvolvimento de um sistema espectrofotométrico portátil que emprega um dispositivo 3D para acoplamento de uma câmera webcam como sistema de detecção; o sistema é totalmente alimentado por portas USB de um computador e faz uso de um LED como fonte de radiação, alimentado por uma fonte de tensão ajustável. O desempenho preliminar do sistema foi avaliado em determinações de ferro (II) e hipoclorito, utilizando os dados de cor do espaço RGB e o processamento matemático absorvância efetiva. O sistema apresentou bom desempenho analítico posicionando o LED no topo da cubeta e fonte de radiação com máxima intensidade. O terceiro capítulo apresenta a aplicação do sistema espectrofotométrico desenvolvido na determinação do marcador externo, dióxido de titânio, em fezes bovina. O método apresentou limites de detecção e quantificação de 0,57 e 0,85 mg 100 g-1, respectivamente; faixa linear de trabalho de 0,85 a 10 mg 100 g-1 e precisão, expressa em termos de DPR, de 1,86%. A exatidão do método foi verificada comparando os resultados encontrados pelo método proposto com o método espectrofotométrico de referência e não observou-se diferença significativa. O quarto capítulo apresenta um sistema fluorimétrico portátil, que faz uso de um LED monocromático na etapa de excitação, para determinação de quinina em amostras comerciais de água tônica. O sistema apresentou desempenho satisfatório, com faixa linear de trabalho de 0,99 a 10 mg L-1, coeficiente de determinação igual a 0,9980 e precisão (DPR) média de 1,14%. As amostras apresentaram teores de quinina de 47,8 a 66,7 mg L-1, dentro dos padrões estabelecidos pela legislação vigente. Os sistemas desenvolvidos apresentaram bom desempenho, mostrando-se como alternativas promissoras aos métodos de referência, para determinações analíticas baseadas em análise de imagem digital.pt_BR
dc.publisher.departmentInstituto de Químicapt_BR
dc.type.degreeDoutoradopt_BR
Appears in Collections:Tese (Química)

Files in This Item:
File Description SizeFormat 
Tese - Cheilane Souza.pdfTese Doutorado de Cheilane Tavares de Souza2,44 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.