Please use this identifier to cite or link to this item: https://repositorio.ufba.br/handle/ri/27623
metadata.dc.type: Artigo de Periódico
Title: Multivariate optimization of a procedure employing microwave-assisted digestion for the determination of nickel and vanadium in crude oil by ICP OES.
Authors: Anjos, Shirlei
Alves, Jeferson
Soares, Sarah
Araujo, Rennan
Oliveira, Olivia
Queiroz, Antonio Fernando
Ferreira, Sergio Luis Costa
metadata.dc.creator: Anjos, Shirlei
Alves, Jeferson
Soares, Sarah
Araujo, Rennan
Oliveira, Olivia
Queiroz, Antonio Fernando
Ferreira, Sergio Luis Costa
Abstract: This work presents the optimization of a sample preparation procedure using microwave-assisted digestion for the determination of nickel and vanadium in crude oil employing inductively coupled plasma optical emission spectrometry (ICP OES). The optimization step was performed utilizing a two-level full factorial design involving the following factors: concentrated nitric acid and hydrogen peroxide volumes, and microwave-assisted digestion temperature. Nickel and vanadium concentrations were used as responses. Additionally, a multiple response based on the normalization of the concentrations by the highest values was built to establish a compromise condition between the two analytes. A Doehlert matrix optimized the instrumental conditions of the ICP OE spectrometer. In this design, the plasma robustness was used as chemometric response. The experiments were performed using a digested oil sample solution doped with magnesium(II) ions, as well as a standard magnesium solution. The optimized method allows for the determination of nickel and vanadium with quantification limits of 0.79 and 0.20 μg g−1 , respectively, for a digested sample mass of 0.1 g. The precision (expressed as relative standard deviations) was determined using five replicates of two oil samples and the results obtained were 1.63% and 3.67% for nickel and 0.42% and 4.64% for vanadium. Bismuth and yttrium were also tested as internal standards, and the results demonstrate that yttrium allows for a better precision for the method. The accuracy was confirmed by the analysis of the certified reference material trace element in fuel oil (CRM NIST 1634c). The proposed method was applied for the determination of nickel and vanadium in five crude oil samples from Brazilian Basins. The metal concentrations found varied from 7.30 to 33.21 μg g−1 for nickel and from 0.63 to 19.42 μg g−1 for vanadium.
Keywords: nickel
vanadium
crude oil
experimental multivariate
ICP OES
microwave assisted digestion
metadata.dc.publisher.country: Brasil
Publisher: Elsevier
Citation: ANJOS, Shirlei L. dos et al. Multivariate optimization of a procedure employing microwave-assisted digestion for the determination of nickel and vanadium in crude oil by ICP OES. Talanta, London, v. 178, p. 842-846, fev. 2018. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0039914017310494>. Acesso em: 04 out. 2018.
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/27623
Issue Date: 2018
Appears in Collections:Artigo Publicado em Periódico (POSPETRO)

Files in This Item:
File Description SizeFormat 
1-s2.0-S0039914017310494-main.pdf294,27 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.