Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/14895
metadata.dc.type: Artigo de Periódico
Título : Comparison of Fit Accuracy between Procera® Custom Abutments and Three Implant Systems
Otros títulos : Clinical Implant Dentistry and Related Research
Autor : Cunha, Tiago de Morais Alves da
Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
metadata.dc.creator: Cunha, Tiago de Morais Alves da
Araújo, Roberto Paulo Correia de
Rocha, Paulo Vicente Barbosa da
Amoedo, Rosa Maria Pazos
Resumen : Background: Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. Purpose: The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with implants from the same manufacturer (Procera manufacturer) and two other implant systems. Materials and Methods: Twenty-four zirconia Procera abutments were produced using computer-assisted design and manufacture and paired with (a) eight MK III, RP 4.1 × 10 mm implants (Nobel Biocare™, Göteborg, Sweden) – GNB group (Nobel Biocare group); (b) eight Try on, 4.1 × 10 mm implants (Sistema de Implantes, São Paulo, Brazil) – ES group (SIN experimental group) ; and (c) eight Master screw, 4.1 × 10 mm implants (Conexão® Sistema de Prótese, São Paulo, Brazil) – EC group (Conexão experimental group). A comparison of the vertical misfit at the implant–abutment interface was taken at six measuring sites on each sample using scanning electron microscopy with a magnification of 408×. One-way analysis of variance was used to test for differences, and Tukey's test was used for pair-wise comparison of groups (α = 0.05). Results: Significant differences relative to average misfit were found when Procera abutments were associated with other implant manufacturers. The ES group and EC group did not differ significantly, but both demonstrated significantly larger average misfit than the GNB group (p = .001). The average misfit was 5.7 µm ± 0.39, 9.53 µm ± 0.52, and 10.62 µm ± 2.16, respectively, for groups GNB, ES, and EC. Conclusion: The association of Procera zirconia abutment with other implant systems different from its manufacturer demonstrated significant alteration of vertical misfit at implant–abutment interface.
Palabras clave : Dental implants
Implant-supported prosthesis;
Misfit
Prosthodontic planning
metadata.dc.rights: Acesso Aberto
URI : http://repositorio.ufba.br/ri/handle/ri/14895
Fecha de publicación : 2012
Aparece en las colecciones: Artigo Publicado em Periódico (ICS)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Tiago de Morais Alves da Cunha.pdf330,2 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.