RI UFBA >
Instituto de Geociências >
Programa de Pós-Graduação em Geoquímica: Petróleo e Meio Ambiente (POSPETRO) >
Artigos Publicados em Periódicos (POSPETRO) >
Please use this identifier to cite or link to this item:
http://repositorio.ufba.br/ri/handle/ri/27623
|
Title: | Multivariate optimization of a procedure employing microwave-assisted digestion for the determination of nickel and vanadium in crude oil by ICP OES. |
Authors: | Anjos, Shirlei Alves, Jeferson Soares, Sarah Araujo, Rennan Oliveira, Olivia Queiroz, Antonio Fernando Ferreira, Sergio Luis Costa |
Keywords: | nickel;vanadium;crude oil;experimental multivariate;ICP OES;microwave assisted digestion |
Issue Date: | 2018 |
Publisher: | Elsevier |
Citation: | ANJOS, Shirlei L. dos et al. Multivariate optimization of a procedure employing microwave-assisted digestion for the determination of nickel and vanadium in crude oil by ICP OES. Talanta, London, v. 178, p. 842-846, fev. 2018. Disponível em: <https://www.sciencedirect.com/science/article/pii/S0039914017310494>. Acesso em: 04 out. 2018. |
Abstract: | This work presents the optimization of a sample preparation procedure using microwave-assisted digestion for
the determination of nickel and vanadium in crude oil employing inductively coupled plasma optical emission
spectrometry (ICP OES). The optimization step was performed utilizing a two-level full factorial design involving
the following factors: concentrated nitric acid and hydrogen peroxide volumes, and microwave-assisted digestion
temperature. Nickel and vanadium concentrations were used as responses. Additionally, a multiple response
based on the normalization of the concentrations by the highest values was built to establish a compromise
condition between the two analytes. A Doehlert matrix optimized the instrumental conditions of the ICP OE
spectrometer. In this design, the plasma robustness was used as chemometric response. The experiments were
performed using a digested oil sample solution doped with magnesium(II) ions, as well as a standard magnesium
solution. The optimized method allows for the determination of nickel and vanadium with quantification limits
of 0.79 and 0.20 μg g−1
, respectively, for a digested sample mass of 0.1 g. The precision (expressed as relative
standard deviations) was determined using five replicates of two oil samples and the results obtained were
1.63% and 3.67% for nickel and 0.42% and 4.64% for vanadium. Bismuth and yttrium were also tested as
internal standards, and the results demonstrate that yttrium allows for a better precision for the method. The
accuracy was confirmed by the analysis of the certified reference material trace element in fuel oil (CRM NIST
1634c). The proposed method was applied for the determination of nickel and vanadium in five crude oil
samples from Brazilian Basins. The metal concentrations found varied from 7.30 to 33.21 μg g−1 for nickel and
from 0.63 to 19.42 μg g−1 for vanadium. |
URI: | http://repositorio.ufba.br/ri/handle/ri/27623 |
ISSN: | 0039-9140 |
Appears in Collections: | Artigos Publicados em Periódicos (POSPETRO)
|
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|