Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14954
Tipo: Artigo de Periódico
Título: New bone formation around implants inserted on autologous and xenografts irradiated or not with IR laser light: a histomorphometric study in rabbits
Título(s) alternativo(s): Brazilian Dental Journal
Autor(es): Soares, Luiz Guilherme Pinheiro
Magalhães Júnior, Edival Barreto de
Magalhães, Cesar Augusto B.
Ferreira, Cimara Fortes
Marques, Aparecida Maria C.
Pinheiro, Antonio Luiz Barbosa
Autor(es): Soares, Luiz Guilherme Pinheiro
Magalhães Júnior, Edival Barreto de
Magalhães, Cesar Augusto B.
Ferreira, Cimara Fortes
Marques, Aparecida Maria C.
Pinheiro, Antonio Luiz Barbosa
Abstract: Use of biomaterials and light on bone grafts has been widely reported. This work assessed the influence of low-level laser therapy (LLLT) on bone volume (BV) and bone implant contact (BIC) interface around implants inserted in blocks of bovine or autologous bone grafts (autografts), irradiated or not, in rabbit femurs. Twenty-four adult rabbits were divided in 8 groups: AG: autograft; XG: xenograft; AG/L: autograft + laser; XG/L: xenograft + laser; AG/I: autograft + titanium (Ti) implant; XG/I: xenograft + Ti implant; AG/I/L: autograft + Ti implant + laser; and XG/I/L: xenograft + Ti implant + laser. The animals received the Ti implant after incorporation of the grafts. The laser parameters in the groups AG/L and XG/L were λ=780 nm, 70 mW, CW, 21.5 J/cm 2 , while in the groups AG/I/L and XG/I/L the following parameters were used: λ=780 nm, 70 mW, 0.5 cm 2 (spot), 4 J/cm 2 per point (4), 16 J/cm 2 per session, 48 h interval × 12 sessions, CW, contact mode. LLLT was repeated every other day during 2 weeks. To avoid systemic effect, only one limb of each rabbit was double grafted. All animals were sacrificed 9 weeks after implantation. Specimens were routinely stained and histomorphometry carried out. Comparison of non-irradiated and irradiated grafts (AG/L versus AG and XG/L versus XG) showed that irradiation increased significantly BV on both grafts (p=0.05, p=0.001). Comparison between irradiated and non-irradiated grafts (AG/I/L versus AG/I and XG/I/L versus XG/I) showed a significant (p=0.02) increase of the BIC in autografts. The same was seen when xenografts were used, without significant difference. The results of this investigation suggest that the use of LLLT is effective for enhancing new bone formation with consequent increase of bone-implant interface in both autologous grafts and xenografts.
Palavras-chave: Bone repair
Low-level laser therapy
País: Brasil
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/14954
Data do documento: 2013
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
0103-6440-bdj-24-03-218.pdf2,18 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.