Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/8339
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorAndrade, Jailson Bittencourt de-
dc.contributor.authorNunes, Genebaldo S.-
dc.contributor.authorVeiga, Merilio P.-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorAmorim, Adelaide Maria Mendonça-
dc.contributor.authorReis, Selma T.-
dc.creatorAndrade, Jailson Bittencourt de-
dc.creatorNunes, Genebaldo S.-
dc.creatorVeiga, Merilio P.-
dc.creatorCosta, Antonio Celso Spinola-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorAmorim, Adelaide Maria Mendonça-
dc.creatorReis, Selma T.-
dc.date.accessioned2013-02-04T15:18:56Z-
dc.date.issued1997-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/8339-
dc.descriptionTexto completo: acesso restrito. p.165-168pt_BR
dc.description.abstractThe use of 85% phosphoric acid in borosilicate conical flasks for the dissolution of ilmenites at 230 ± 10°C is reported. The samples were quantitatively dissolved in less than 13 min. Titanium was determined by both spectrophotometry and inductively coupled plasma atomic emission spectrometry ICP-AES. Vanadium and iron were determined by ICP-AES. In several samples of ilmenites analyzed, the TiO2 concentration was in the range 10.6–57.5% and those of FeO and V2O5 were in the ranges 31.6–51.4% and 0.39–1.32%, respectively. In the spectrophotometric method, vanadium interference occurs only when the View the MathML source concentration ratio is <4. In all samples analyzed this ratio was around 12, resulting in no interferences due to vanadium. Hence the ilmenite dissolution procedure using phosphoric acid was compatible with titanium quantification by both spectrophotometry and ICP-AES.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0039-9140(96)02026-7pt_BR
dc.subjectInductively coupled plasma atomic emission spectrometrypt_BR
dc.subjectllmenitespt_BR
dc.subjectPhosphoric acid dissolutionpt_BR
dc.subjectSpectrophotometrypt_BR
dc.subjectTitaniumpt_BR
dc.titleSpectrophotometric and inductively coupled plasma atomic emission spectrometric determination of titanium in ilmenites after rapid dissolution with phosphoric acidpt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 44, n. 2pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Andrade.pdf
  Restricted Access
251,23 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.