Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7756
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCassella, Ricardo Jorgensen-
dc.contributor.authorSalim, Veronica A.-
dc.contributor.authorJesuı́no, Luciene S.-
dc.contributor.authorSantelli, Ricardo Erthal-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCarvalho, Marcelo Souza de-
dc.creatorCassella, Ricardo Jorgensen-
dc.creatorSalim, Veronica A.-
dc.creatorJesuı́no, Luciene S.-
dc.creatorSantelli, Ricardo Erthal-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCarvalho, Marcelo Souza de-
dc.date.accessioned2013-01-04T14:13:46Z-
dc.date.issued2001-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7756-
dc.descriptionTexto completo: acesso restrito. p. 61–67pt_BR
dc.description.abstractThis paper reports the development of a new methodology for determination of cobalt in water samples by using a flow injection system with loaded PUF as solid phase to preconcentrate analytes. Procedure is based on on-line retention of Co(III) ions (generated in alkaline medium by Co(II) oxidation) in a minicolumn packed with a polyether type polyurethane foam loaded with TAC (2-(2-thiazolylazo)-p-cresol) and elution with 2 mol l−1 HCl directly to the flame atomic absorption spectrometer nebulizer. Several chemical and flow variables that could affect the performance of this system were investigated as well as the possible interferents. For 2 min of preconcentration time (10.0 ml of sample volume) the system achieved a detection limit 3.2 μg l−1, a R.S.D. 5% at 20 μg l−1 and an analytical throughput 24 h−1. Whereas for 3 min of preconcentration time (15.0 ml of sample volume) a detection limit 2.4 μg l−1, a R.S.D. under 8% at 10 μg l−1 and a sampling frequency 17 h−1 were reported.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0039-9140(00)00626-3pt_BR
dc.subjectPolyurethane foampt_BR
dc.subjectCobaltpt_BR
dc.subjectSolid phase extractionpt_BR
dc.subjectFlow injection analysispt_BR
dc.titleFlow injection determination of cobalt after its sorption onto polyurethane foam loaded with 2-(2-thiazolylazo)-p-cresol (TAC)pt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 54, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Ferreira.pdf
  Restricted Access
103,81 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.