Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7679
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLemos, Valfredo Azevedo-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorLemos, Valfredo Azevedo-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2012-12-19T18:04:15Z-
dc.date.issued2001-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7679-
dc.descriptionTexto completo: acesso restrito. p. 281–289pt_BR
dc.description.abstractIn the present paper, an on-line system for enrichment and determination of lead is proposed. It is based on the chemical sorption of lead(II) ions on a minicolumn packed with polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresol (BTAC) reagent. After preconcentration, lead(II) ions are eluted by 0.10 mol l−1 hydrochloric acid solution and determined directly by flame atomic absorption spectrometry (FAAS). Chemical and flow variables as well as effect of other ions were studied. The results demonstrated that lead could be determinate with an enrichment factor of 26 for a sample volume of 7.0 ml and preconcentration time of 1 min. The detection limit (3 s) was 1.0 μg l−1 and the precision (assessed as the relative standard deviation) reached values of 6.0–0.7% in lead solutions of 10–500 μg l−1 concentration, respectively. The enrichment factor and the detection limit can be further improved by increasing preconcentration time without degradation in the efficiency due to the favorable kinetics and low hydrodynamic impedance of the present system. Achieved sampling frequency was 48 samples per hour. The effect of another ions in concentrations agreeing with biological samples was studied. It was found that the proposed procedure has necessary selectivity for lead determination in seafood and other biological samples. The accuracy was confirmed by analysis of the followings certified reference materials: fish tissue IAEA, lobster hepatopancreas NRCC TORT-1 and citrus leaves NIST 1572. Recoveries of spike additions (0.2 or 1.0 μg g−1) to several seafood samples were quantitative (90–107%). These results proved also that the procedure is not affected by matrix interferences and can be applied satisfactorily for lead determination in samples of shrimp, oyster, crab, fish and mussel contaminated by it.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0003-2670(01)01125-4pt_BR
dc.subjectPreconcentrationpt_BR
dc.subjectSeafoodpt_BR
dc.subjectPolyurethanept_BR
dc.titleOn-line preconcentration system for lead determination in seafood samples by flame atomic absorption spectrometry using polyurethane foam loaded with 2-(2-benzothiazolylazo)-2-p-cresolpt_BR
dc.title.alternativeAnalytica Chimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 441, n. 2pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S0003267001011254-main.pdf
  Restricted Access
157,02 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.