Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7605
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorTeixeira, Leonardo Sena Gomes-
dc.contributor.authorRocha, Fábio Rodrigo Piovezani-
dc.contributor.authorKorn, Mauro-
dc.contributor.authorReis, Boaventura F.-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.creatorTeixeira, Leonardo Sena Gomes-
dc.creatorRocha, Fábio Rodrigo Piovezani-
dc.creatorKorn, Mauro-
dc.creatorReis, Boaventura F.-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCosta, Antonio Celso Spinola-
dc.date.accessioned2012-12-17T16:38:06Z-
dc.date.issued1999-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7605-
dc.descriptionTexto completo: acesso restrito, p.309-315pt_BR
dc.description.abstractA flow system exploiting solid-phase spectrophotometry is proposed for the determination of zinc in pharmaceutical preparations. The chromogenic reagent 1-(2-tiazolylazo)-2-naphthol (TAN) was immobilized on C18 bonded silica loaded into a homemade flow cell with 1 mm optical path and 78 mm2 cross section. The flow cell was designed in such a way that the sensitivity is enhanced and the attenuation of the radiation beam due to scattering and absorption by the solid material is minimized. The flow cell was placed in the spectrophotometer so that the radiation beam was focused on the overall surface containing the adsorbing material. Reagent immobilization was performed on-line and allowed to work for at least one month. Analyte reaction, retention and detection were performed simultaneously, followed by elution with hydrochloric acid. The apparent molar absorptivity was estimated as 2.02×105 l mol−1 cm−1 and the procedure allowed the determination of zinc in the 0.04–4.0 mg l−1 range with a coefficient of variation of 3.3% (n=10). A sample throughput of 45 determinations per hour and a detection limit of 10 μg l−1 (99.7% confidence level) were achieved. The results agreed at a 95% confidence level with those found by inductively coupled plasma atomic emission spectrometry.pt_BR
dc.language.isoenpt_BR
dc.publisherElservierpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0003-2670(98)00792-2pt_BR
dc.subjectSolid-phase spectrophotometrypt_BR
dc.subjectFlow-injection analysispt_BR
dc.subjectZinc determinationpt_BR
dc.subjectPharmaceutical preparationspt_BR
dc.titleFlow-injection solid-phase spectrophotometry for the determination of zinc in pharmaceutical preparationspt_BR
dc.title.alternativeAnalytica Chimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 383, n. 3pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Teixeira.pdf
  Restricted Access
163,28 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.