Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7461
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLemos, Valfredo Azevedo-
dc.contributor.authorGuardia, Miguel de la-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorLemos, Valfredo Azevedo-
dc.creatorGuardia, Miguel de la-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2012-12-12T16:18:26Z-
dc.date.issued2002-09-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7461-
dc.descriptionTexto completo: acesso restrito. p. 475-480pt_BR
dc.description.abstractA flow injection method has been developed for the direct determination of free available Pb(II) and total Pb content in wine samples. The method is based on the chemical sorption of Pb(II), from pH 7 buffered solutions, on a packed polyurethane foam column, modified by addition of 2-(2-benzothiazolylazo)-p-cresol (BTAC). After this step, lead was directly eluted with a stream of 0.1 mol l−1 HCl into an air C2H2 flame in which lead was determined by atomic absorption spectrometry. Total lead was analyzed after sample digestion with nitric acid and hydrogen peroxide, being free available lead determined by direct sample on-line preconcentration and elution. The method provides a limit of detection (3σ) of 1 μg l−1 lead and relative standard deviation, which varies from 6 to 0.7% for lead concentration of 10 and 500 μg l−1. Total content of lead in wine samples analyzed varied from 8 to 42 μg l−1 being obtained free available values of Pb(II) under the limit of detection of the method. Recovery studies on natural wine samples, spicked with inorganic lead, evidenced the remaining capability of ligands, present in the wine, to avoid lead retention on the polyurethane foam loaded with BTAC.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0039-9140(02)00325-9pt_BR
dc.subjectLeadpt_BR
dc.subjectWinept_BR
dc.subjectFAASpt_BR
dc.subjectOn-linept_BR
dc.titleAn on-line system for preconcentration and determination of lead in wine samples by FAASpt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 58, n. 3pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S0039914002003259-main.pdf
  Restricted Access
122,33 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.