Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7319
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.contributor.authorBezerra, Marcos de Almeida-
dc.contributor.authorLemos, Valfredo Azevedo-
dc.contributor.authorBosque-Sendra, Juan Manuel-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorSantos, Walter Nei Lopes dos-
dc.creatorBezerra, Marcos de Almeida-
dc.creatorLemos, Valfredo Azevedo-
dc.creatorBosque-Sendra, Juan Manuel-
dc.date.accessioned2012-12-07T14:08:11Z-
dc.date.issued2003-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/7319-
dc.descriptionTexto Completo: acesso restrito. p. 443–449.pt_BR
dc.description.abstractA system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5 dimethylaminophenol (TAM). The optimisation step was carried out using twolevel full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 μgL–1, and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 μgL–1, respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://download.springer.com/static/pdf/585/art%253A10.1007%252Fs00216-002-1695-y.pdf?auth66=1355061502_32a529815bcdc67ed921b43f5aeb16f9&ext=.pdfpt_BR
dc.subjectLead determinationpt_BR
dc.subjectDoehlert matrixpt_BR
dc.subjectOn-line preconcentrationpt_BR
dc.subjectPolyurethane foampt_BR
dc.subjectFAASpt_BR
dc.titleUse of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometrypt_BR
dc.title.alternativeAnalytical and Bioanalytical Chemistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 375, n. 5pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
art%253A10.1007%252Fs00216-002-1695-y.pdf
  Restricted Access
671,63 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.