https://repositorio.ufba.br/handle/ri/7319
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Ferreira, Sergio Luis Costa | - |
dc.contributor.author | Santos, Walter Nei Lopes dos | - |
dc.contributor.author | Bezerra, Marcos de Almeida | - |
dc.contributor.author | Lemos, Valfredo Azevedo | - |
dc.contributor.author | Bosque-Sendra, Juan Manuel | - |
dc.creator | Ferreira, Sergio Luis Costa | - |
dc.creator | Santos, Walter Nei Lopes dos | - |
dc.creator | Bezerra, Marcos de Almeida | - |
dc.creator | Lemos, Valfredo Azevedo | - |
dc.creator | Bosque-Sendra, Juan Manuel | - |
dc.date.accessioned | 2012-12-07T14:08:11Z | - |
dc.date.issued | 2003 | - |
dc.identifier.issn | 1618-2642 | - |
dc.identifier.uri | http://www.repositorio.ufba.br/ri/handle/ri/7319 | - |
dc.description | Texto Completo: acesso restrito. p. 443–449. | pt_BR |
dc.description.abstract | A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5 dimethylaminophenol (TAM). The optimisation step was carried out using twolevel full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 μgL–1, and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 μgL–1, respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food. | pt_BR |
dc.language.iso | en | pt_BR |
dc.source | http://download.springer.com/static/pdf/585/art%253A10.1007%252Fs00216-002-1695-y.pdf?auth66=1355061502_32a529815bcdc67ed921b43f5aeb16f9&ext=.pdf | pt_BR |
dc.subject | Lead determination | pt_BR |
dc.subject | Doehlert matrix | pt_BR |
dc.subject | On-line preconcentration | pt_BR |
dc.subject | Polyurethane foam | pt_BR |
dc.subject | FAAS | pt_BR |
dc.title | Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry | pt_BR |
dc.title.alternative | Analytical and Bioanalytical Chemistry | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.identifier.number | v. 375, n. 5 | pt_BR |
dc.embargo.liftdate | 10000-01-01 | - |
Aparece nas coleções: | Artigo Publicado em Periódico (Química) |
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
art%253A10.1007%252Fs00216-002-1695-y.pdf Restricted Access | 671,63 kB | Adobe PDF | Visualizar/Abrir Solicitar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.