Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/7199
Tipo: Artigo de Periódico
Artigo de Periódico
Título: Improving the signal data acquisition in condition monitoring of electrical machines
Título(s) alternativo(s): IEEE Transactions on Instrumentation and Measurement
Autor(es): Costa, Fernando Ferreira
Almeida, Luiz Alberto Luz de
Naidu, S. R.
Member, Senior
Braga-Filho, E. R.
Autor(es): Costa, Fernando Ferreira
Almeida, Luiz Alberto Luz de
Naidu, S. R.
Member, Senior
Braga-Filho, E. R.
Abstract: The occurrence of a broken bar in induction machines causes an internal magnetic imbalance, which is reflected in the stator current. This effect may be detected by estimating the spectral signature of the stator current, particularly the sidebands around the fundamental frequency. However, the fundamental 60-Hz amplitude is considerably greater than the sideband amplitude, which usually requires an analog 60-Hz notch filter in the data acquisition system. Analog filters are sensitive to temperature variations, which, in this case, may shift the filter resonance frequency and degrade the desired response. It is proposed in this paper that the analog notch filter may be replaced by a digital/analog cancelling technique based on the recursive discrete-time Fourier transform. The technique is shown to attenuate the fundamental 60-Hz amplitude considerably before A/D conversion, leaving only the sidebands in the current signal
Palavras-chave: Condition monitoring
induction motor
motor current signature analysis (MCSA)
preventive maintenance
URI: http://www.repositorio.ufba.br/ri/handle/ri/7199
Data do documento: 2004
Aparece nas coleções:Artigo Publicado em Periódico (PEI)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
01315977.pdf
  Restricted Access
487,45 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.