dc.descriptionp.401-404pt_BR
dc.description.abstractThe evaluation of the salivary flow rate is important in several situations of dental practice. However, weighing the collected salivary volume it is not a practical method in public health services. This work evaluated the use of hypodermic graduated syringes as a simpler alternative method to measure the salivary flow rate. Saliva samples were obtained from 50 individuals (31 females and 19 males) aged 8 to 32 years (mean age: 12.4 years), recruited at the outpatient dental clinics of two public health centers. After collection, the saliva was weighed in a graduated scale and the results compared with the volume obtained through its measurement, in mL, in graduated hypodermic syringes. There was a positive and significant relationship between the two methods of measuring salivary flow rates as demonstrated by the Pearson’s correlation coefficient (r = 0.996, with p<0.05). Measurement of the salivary flow rate using graduated syringes demonstrated to be a reliable method, with lower cost and more practical than the traditional method of salivary weighing.pt_BR
dc.language.isoenpt_BR
dc.publisherFundação Odontológica de Ribeirão Pretopt_BR
dc.sourcehttp://dx.doi.org/10.1590/S0103-64402010000500004pt_BR
dc.subjectSalivapt_BR
dc.subjectOral healthpt_BR
dc.subjectSialometrypt_BR
dc.subjectPublic healthpt_BR
dc.titleUse of graduated syringes for measuring salivary flow rate: a pilot studypt_BR
dc.title.alternativeBrazilian Dental Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.description.localpubRibeirão Pretopt_BR
dc.identifier.numberv. 21, n. 5pt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Medicina)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Alves, Crésio(2).pdf263,67 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.