Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6696
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCruz, Lícia Passos dos Santos-
dc.contributor.authorCampos, Vânia Palmeira-
dc.contributor.authorSilva, Adriana M. C.-
dc.contributor.authorTavares, Tânia Mascarenhas-
dc.creatorCruz, Lícia Passos dos Santos-
dc.creatorCampos, Vânia Palmeira-
dc.creatorSilva, Adriana M. C.-
dc.creatorTavares, Tânia Mascarenhas-
dc.date.accessioned2012-09-05T17:05:58Z-
dc.date.issued2004-
dc.identifier.issn1352-2310-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6696-
dc.descriptionTrabalho completo: acesso restrito, p. 6425–6429pt_BR
dc.description.abstractPassive samplers have been widely used for over 30 years in the measurement of personal exposure to vapours and gases in the workplace. These samplers have just recently been applied in the monitoring of ambient air, which presents concentrations that are normally much smaller than those found in occupational environments. The locally constructed passive sampler was based on gas molecular diffusion through static air layer. The design used minimizes particle interference and turbulent diffusion. After exposure, the SO2 trapped in impregnated filters with Na2CO3 was extracted by means of an ultrasonic bath, for 15 min, using 1.0×10−2 mol L−1 H2O2. It was determined as SO4−2 by ion chromatography. The performance of the passive sampler was evaluated at different exposure periods, being applied in industrial and urban areas. Method precision as relative standard deviation for three simultaneously applied passive samplers was within 10%. Passive sampling, when compared to active monitoring methods under real conditions, used in urban and industrial areas, showed an overall accuracy of 15%. A statistical comparison with an active method was performed to demonstrate the validity of the passive method. Sampler capacity varied between 98 and 421 μg SO2 m−3 for exposure periods of one month and one week, respectively, which allows its use in highly polluted areas.pt_BR
dc.language.isoenpt_BR
dc.publisherElsevierpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.atmosenv.2004.07.022,pt_BR
dc.subjectPassive samplingpt_BR
dc.subjectSulphur dioxidept_BR
dc.subjectDiffusive samplerpt_BR
dc.subjectEnvironment monitoringpt_BR
dc.subjectBrazilpt_BR
dc.titleA field evaluation of a SO2 passive sampler in tropical industrial and urban airpt_BR
dc.title.alternativeAtmospheric Environmentpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 38, n. 37pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
(197).pdf
  Restricted Access
217,68 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.