Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6586
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorAraújo, Cristiano Venícius de Matos-
dc.contributor.authorNascimento, Renato B.-
dc.contributor.authorOliveira, Carla A.-
dc.contributor.authorStrotmann, Uwe J.-
dc.contributor.authorSilva, Eduardo Mendes da-
dc.creatorAraújo, Cristiano Venícius de Matos-
dc.creatorNascimento, Renato B.-
dc.creatorOliveira, Carla A.-
dc.creatorStrotmann, Uwe J.-
dc.creatorSilva, Eduardo Mendes da-
dc.date.accessioned2012-08-13T20:01:02Z-
dc.date.issued2005-03-
dc.identifier.issn0045-6535-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6586-
dc.descriptionTrabalho completo: acesso restrito, p. 1277–1281pt_BR
dc.description.abstractThe treatment efficiency, as toxicity removal, of complex effluents from the Industrial District of Camaçari (BA, Brazil), after biological treatment with activated sludge was evaluated using Microtox®. Samples of the equalised effluent (EE) were collected prior to treatment together with samples of the treated effluent (TE), which remained 24 h in the treatment plant. Rehydrated colonies of Vibrio fischeri were exposed to sequential dilutions of EE and TE to assess luminosity interference. Values for EC50 were calculated, together with the respective toxicity units. In all, twenty assays of each effluent type were carried out and the mean toxicity removal was 92.71%, while the chemical oxygen demand (COD) presented mean reduction of 83.04%. There was a variability of an order of magnitude between the Microtox® results for the two types of effluents. The mean EC50 values were 2.12 for EE and 47.78% for TE. In spite of its weakness in some conditions, the Microtox® system demonstrated to work adequately in assessing effluent toxicity removal in this treatment plant and therefore can be used for further toxicity removal programs.pt_BR
dc.language.isoenpt_BR
dc.publisherElsevierpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.chemosphere.2004.10.036pt_BR
dc.subjectActivated sludgept_BR
dc.subjectEcotoxicitypt_BR
dc.subjectLuminescent bacteria testpt_BR
dc.subjectToxicity reductionpt_BR
dc.subjectWastewater treatment plantpt_BR
dc.titleThe use of Microtox® to assess toxicity removal of industrial effluents from the industrial district of Camaçari (BA, Brazil)pt_BR
dc.title.alternativeChemospherept_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 58, n. 9pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Biologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
(158).pdf
  Restricted Access
174,65 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.