Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6441
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBispo, Márcia Sousa-
dc.contributor.authorBoa Morte, Elane Santos da-
dc.contributor.authorKorn, Maria das Graças Andrade-
dc.contributor.authorTeixeira, Leonardo Sena Gomes-
dc.contributor.authorKorn, Mauro-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.creatorBispo, Márcia Sousa-
dc.creatorBoa Morte, Elane Santos da-
dc.creatorKorn, Maria das Graças Andrade-
dc.creatorTeixeira, Leonardo Sena Gomes-
dc.creatorKorn, Mauro-
dc.creatorCosta, Antonio Celso Spinola-
dc.date.accessioned2012-07-17T15:21:25Z-
dc.date.issued2005-06-03-
dc.identifier.issn0584-8547-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6441-
dc.descriptionTrabalho completo: acesso restrito, p.653–658pt_BR
dc.description.abstractA simple and efficient procedure for separation and pre-concentration using ultrasound-assisted co-precipitation with manganese dioxide was developed for Pb determination by inductively coupled plasma optical emission spectrometry (ICP OES). The optimization process was carried out using a two-level factorial design and a Doehlert matrix. Three variables (i.e. concentration of oxidizing solution—KMnO4, concentration of MnSO4 solution and time of ultrasonic irradiation) were used as factors in the optimization. The recoveries, based on the analysis of spiked samples, were between 90% and 105%, and the precision was ≤ 5%. The detection limit and quantification limit for Pb determination were 3.2 and 10.7 μg L− 1, respectively. The proposed method was applied for the determination of Pb in water samples from a river heavily polluted by industrial effluents. The recovery measured by analyte addition technique showed that the proposed pre-concentration method had good accuracy.pt_BR
dc.language.isoenpt_BR
dc.publisherElsevierpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.sab.2005.02.011pt_BR
dc.subjectLeadpt_BR
dc.subjectCo-precipitationpt_BR
dc.subjectUltrasonic irradiationpt_BR
dc.subjectPre-concentrationpt_BR
dc.titleDetermination of Pb in river water samples by inductively coupled plasma optical emission spectrometry after ultrasound-assisted co-precipitation with manganese dioxidept_BR
dc.title.alternativeSpectrochimica Acta Part B: Atomic Spectroscopypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 60, n. 5pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
(126).pdf
  Restricted Access
178,06 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.