Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6344
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBezerra, Marcos de Almeida-
dc.contributor.authorBruns, Roy Edward-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorBezerra, Marcos de Almeida-
dc.creatorBruns, Roy Edward-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2012-07-05T15:52:08Z-
dc.date.available2012-07-05T15:52:08Z-
dc.date.issued2006-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6344-
dc.descriptionRESTRITOpt_BR
dc.description.abstractA procedure has been developed for the simultaneous determination of traces amounts of Cd, Cr, Cu, Mn, Ni and Pb from saline oil-refinery effluents and digested vegetable samples using inductively coupled plasma optical emission spectrometry (ICP OES). The procedure is based on cloud point extraction (CPE) of these metals as 2-(bromo-2-pyridylazo)-5-diethyl-amino-phenol (Br-PADAP) complexes into a micellar phase of octylphenoxypolyethoxyethanol (Triton X-114). Optimization of the procedure was performed by response surface methodology (RSM) using a Doehlert design. Principal components (PC) were used to simplify the multiple response analysis. A response surface for the first PC score is useful in determining the optimum conditions for the Cd, Cr, Cu, Mn and Pb determinations whereas the second PC is highly correlated with the Ni response. Improvement factors of 22, 36, 46, 25, 65 and 39, along with limits of detection (3σB) of 0.081, 0.79, 0.38, 0.83, 0.28 and 0.69 μg L−1, and precision expressed as relative standard deviation (%R.S.D., n = 8, 20.0 μg L−1) of 1.5, 2.2, 3.5, 2.6, 2.5 and 2.5 were achieved for Cd, Cr, Cu, Mn, Ni and Pb, respectively. The accuracy was evaluated by spike tests in oil-refinery effluent samples and analysis of a vegetable certified reference material (NIST 1571, orchard leaves). Results found were in agreement with certified values.pt_BR
dc.language.isoenpt_BR
dc.publisherAnalytica Chimica Actapt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.aca.2006.07.056pt_BR
dc.subjectCloud point extractionpt_BR
dc.subjectDoehlert designpt_BR
dc.subjectSimultaneous determination in inductively coupled plasma optical emission spectrometry (ICP OES)pt_BR
dc.subjectPrincipal component analysispt_BR
dc.subjectResponse surface analysispt_BR
dc.titleStatistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICP OESpt_BR
dc.title.alternativeAnalytica Chimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv.580, n.2pt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DD.pdf_5407,78 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.