Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6183
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Lisia Maria Gobbo dos-
dc.contributor.authorWelz, Bernhard-
dc.contributor.authorAraujo, Rennan Geovanny Oliveira-
dc.contributor.authorJacob, Silvana do C.-
dc.contributor.authorVale, Maria Goreti R.-
dc.contributor.authorMartens, Andreas-
dc.contributor.authorMartens, Irland B. Gonzaga-
dc.contributor.authorRoss, Helmut Becker-
dc.creatorSantos, Lisia Maria Gobbo dos-
dc.creatorWelz, Bernhard-
dc.creatorAraujo, Rennan Geovanny Oliveira-
dc.creatorJacob, Silvana do C.-
dc.creatorVale, Maria Goreti R.-
dc.creatorMartens, Andreas-
dc.creatorMartens, Irland B. Gonzaga-
dc.creatorRoss, Helmut Becker-
dc.date.accessioned2012-06-19T14:08:40Z-
dc.date.issued2009-
dc.identifier.issn0021-8561-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6183-
dc.descriptionTrabalho completo: acesso restrito, p. 10089–10094pt_BR
dc.description.abstractA fast routine screening method for the simultaneous determination of cadmium and iron in bean and soil samples is proposed, using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling. The primary absorption line at 228.802 nm has been used for the determination of cadmium, and an adjacent secondary line, at 228.726 nm, for iron. Fourteen bean samples and 10 soil samples from nine states all over Brazil have been analyzed. The limits of detection (3 σ, n = 10) were 2.0 μg kg-1 for Cd and 4.5 mg kg-1 for Fe. The relative standard deviation ranged from 4 to 7% for Cd and from 5 to 28% for Fe, which is usually acceptable for a screening method. The accuracy of the method has been confirmed by the analysis of two certified reference materials; the results were in agreement with the certified values at a 95% confidence interval.pt_BR
dc.language.isoenpt_BR
dc.publisherElsevierpt_BR
dc.sourcehttp://pubs.acs.org/doi/pdfplus/10.1021/jf9024773pt_BR
dc.subjectBean and soil samplespt_BR
dc.subjectsimultaneous determination of Cd and Fept_BR
dc.subjecthigh-resolution continuum source AASpt_BR
dc.subjectgraphite furnace atomizationpt_BR
dc.subjectdirect solid sample analysispt_BR
dc.titleSimultaneous Determination of Cd and Fe in Beans and Soil of Different Regions of Brazil Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry and Direct Solid Samplingpt_BR
dc.title.alternativeJournal of Agricultural and Food Chemistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 57, n. 21pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
(79)jf9024773.pdf
  Restricted Access
756,96 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.