Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5619
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorDias, Fábio de Souza-
dc.contributor.authorLovillo, Miguel Palma-
dc.contributor.authorBarroso, Carmelo Garcia-
dc.contributor.authorDavid, Jorge Mauricio-
dc.creatorDias, Fábio de Souza-
dc.creatorLovillo, Miguel Palma-
dc.creatorBarroso, Carmelo Garcia-
dc.creatorDavid, Jorge Mauricio-
dc.date.accessioned2012-04-13T13:03:45Z-
dc.date.issued2010-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/5619-
dc.descriptionAcesso restrito: Texto completo. p. 17-20.pt_BR
dc.description.abstractThe present paper describes a direct procedure for the determination of catechin and epicatechin concentrations in red wines employing reverse-phase high performance liquid chromatography (RP HPLC) and detection by fluorescence. The method was performed using a sample volume of 10 μL without dilution. The separation process employed a Chromolith performance RP-18e (100 mm×4.6 mm) column, and the mobile phase was composed of solvent A: methanol–acetic acid–water (90:8:2) and solvent B: water–acetic acid–methanol (10:2:88) at a flow rate of 1.0 mL min−1. Linearity was observed in the range of 1 to 30 mg L−1, with limits of detection and quantification of 0.27 and 0.89 mg L−1, respectively, for catechin and 0.33 and 1.01 mg L−1, respectively, for epicatechin. The precisions estimated by the relative standard deviation were 3.34 and 1.09% for catechin concentrations of 0.5 and 20 mg L−1 respectively and 2.82 and 0.49% for epicatechin concentrations of 0.5 and 20 mg L−1, respectively. The evaluation of the accuracy was done using an addition/recovery assay. Four wine samples were used, and the recoveries varied from 105 to 108% for catechin and from 97 to 119% for epicatechin. The method was applied to the analysis of red wine samples collected from the São Francisco region, Bahia State, Brazil. Nine samples were analyzed, and the catechin and epicatechin concentrations varied from 7.51 to 73.20 and from 5.08 to 43.32 mg L−1, respectively. The concentrations found agree with data reported in the literature.pt_BR
dc.language.isoenpt_BR
dc.sourceDOI: 10.1016/j.microc.2010.01.004pt_BR
dc.subjectCatechinpt_BR
dc.subjectEpicatechinpt_BR
dc.subjectRed winept_BR
dc.subjectHPLC/fluorescencept_BR
dc.titleOptimization and validation of a method for the direct determination of catechin and epicatechin in red wines by HPLC/fluorescencept_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 96, n. 1.pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...5c8c1d8ed0d16d2304794fdf7447c.pdf
  Restricted Access
185,33 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.