Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5617
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCampos, Vânia Palmeira-
dc.contributor.authorCruz, Lícia Passos dos Santos-
dc.contributor.authorGodoi, Ricardo H. M.-
dc.contributor.authorGodoi, Ana Flávia L.-
dc.contributor.authorTavares, Tânia Mascarenhas-
dc.creatorCampos, Vânia Palmeira-
dc.creatorCruz, Lícia Passos dos Santos-
dc.creatorGodoi, Ricardo H. M.-
dc.creatorGodoi, Ana Flávia L.-
dc.creatorTavares, Tânia Mascarenhas-
dc.date.accessioned2012-04-13T12:42:24Z-
dc.date.issued2010-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/5617-
dc.descriptionAcesso restrito: Texto completo. p. 132-138.pt_BR
dc.description.abstractTraditionally the monitoring of atmospheric pollutants is aimed at managing accidents and short-term actions for the protection of human health on local and regional scales. These monitoring networks required continuous measurements with high time resolution, involving costly equipment, operation and maintenance. More recent simulations with mathematical models and scenario-building on regional, continental and global scales, as well as studies of environmental personal exposure are demanding three main types of monitoring design, where need for special resolution surpasses the one of temporal resolution: remote places, where no electric power nor trained human resources are available; validation of dispersion simulation by mathematical modeling on regional to larger scales; indoor measurements where people are acting under noise restriction such as residences, school and hospitals. To meet these demands environmental passive samplers for atmospheric gaseous pollutants have been developed and applied for different situations and environments of Brazil. Passive samplers were developed based on molecular diffusion of gas through a static layer of air with fixed filters impregnated with a specific solution for SO2, NO2, O3 and H2S and used in the following situations: in remote forest area, urban areas with different characteristics – near the sea, with clean ocean air masses coming in and in areas under direct industrial influence. The passive samplers showed good performance when exposed to different types of areas and during different periods: accuracy of measurements, based on standard deviation, were within the recommended limit by the European Union of ±25% for this type of device and precision below the maximum of 20% cited in the literature, with variation of 2.0 to 16% in the case of these work. The passive devices were able of measuring concentrations very low as those found in the Amazon region (0.58± 0.05 μg m−3 SO2 and 1.10±0.07 μg m−3 NO2) and higher concentrations in industrial areas (20.0±1.3 μg m−3 SO2 e 21.0±1.3 μgm−3 NO2).pt_BR
dc.language.isoenpt_BR
dc.sourceDOI: 10.1016/j.microc.2010.02.015pt_BR
dc.subjectPassive samplerspt_BR
dc.subjectSulfur dioxidept_BR
dc.subjectNitrogen dioxidept_BR
dc.subjectOzonept_BR
dc.subjectAtmospheric monitoringpt_BR
dc.titleDevelopment and validation of passive samplers for atmospheric monitoring of SO2, NO2, O3 and H2S in tropical areaspt_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 96, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...12c67f5cad0293634feac70e91933.pdf
  Restricted Access
421,91 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.