Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5615
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorDuarte, Alvaro T.-
dc.contributor.authorDessuy, Morgana B.-
dc.contributor.authorSilva, Marcia M.-
dc.contributor.authorVale, Maria Goreti R.-
dc.contributor.authorWelz, Bernhard-
dc.creatorDuarte, Alvaro T.-
dc.creatorDessuy, Morgana B.-
dc.creatorSilva, Marcia M.-
dc.creatorVale, Maria Goreti R.-
dc.creatorWelz, Bernhard-
dc.date.accessioned2012-04-13T12:11:40Z-
dc.date.issued2010-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/5615-
dc.descriptionAcesso restrito: Texto completo. p. 102-107pt_BR
dc.description.abstractThe European initiatives to minimize waste electric and electronic equipment (WEEE) and the restriction of hazardous substances (RoHS) had a major impact on the routine control of hazardous substances, including toxic trace metals, such as cadmium and lead, in all kinds of materials that are used in electric and electronic equipment. Instead of analyzing a whole computer, cell phone or television set, individual parts are normally investigated in order to simplify the analytical task. Plastic components are important constituents of electronic equipment, and a potential source of toxic trace metals that are added as catalysts, stabilizers or colorants. As high-tech plastic materials are designed to be resistant against chemical attack, they are usually difficult to bring into solution. A procedure is proposed in the present work that uses direct solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards. The method is sensitive, fast, and it does not require any sample preparation. The limits of detection of 0.1 mg kg−1 for Cd and 0.6 mg kg−1 for Pb are more than adequate for the purpose. Additional means are presented for reducing the sensitivity in order to cope with high analyte concentration. The method has been tested analyzing two certified reference materials, and good agreement with certified values has been obtained.pt_BR
dc.language.isoenpt_BR
dc.sourceDOI: 10.1016/j.microc.2010.02.008pt_BR
dc.subjectWEEEpt_BR
dc.subjectRoHSpt_BR
dc.subjectSolid sampling graphite furnace atomicpt_BR
dc.subjectabsorption spectrometrypt_BR
dc.subjectCdpt_BR
dc.subjectPbpt_BR
dc.subjectPolymerspt_BR
dc.titleDetermination of cadmium and lead in plastic material from waste electronic equipment using solid sampling graphite furnace atomic absorption spectrometrypt_BR
dc.title.alternativeMICROCHEMICAL JOURNALpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 96, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
__ac.els-cdn.com_S002626...d84e8e639092e8466dd4ef67e8ea5.pdf
  Restricted Access
288,51 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.