Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/5024
Tipo: Artigo de Periódico
Título: Application of factorial design and Doehlert matrix in the optimisation of instrumental parameters for direct determination of silicon in naphtha using graphite furnace atomic absorption spectrometry
Título(s) alternativo(s): Journal of Analytical Atomic Spectrometry
Autor(es): Amaro, Joana Angélica de Azerêdo
Ferreira, Sergio Luis Costa
Autor(es): Amaro, Joana Angélica de Azerêdo
Ferreira, Sergio Luis Costa
Abstract: A method for direct determination of silicon in naphtha samples using graphite furnace atomic absorption spectrometry (GFAAS) is proposed. The optimisation of the instrumental conditions was multivariate using a fractional factorial design and Doehlert matrix. Firstly, the fractional factorial design was performed for preliminary evaluation of the significance of the factors, the factors chosen being: sample volume, atomisation temperature, pyrolysis time and pyrolysis temperature. The results demonstrated that the variables sample volume, varying from 10 to 30 mL, and pyrolysis time, from 10 to 40 s, were not significant. However, the variables pyrolysis temperature and atomisation temperature in the levels studied were statistically significant. Because of this, a Doehlert design was performed in order to determine the optimum conditions for pyrolysis and atomisation temperature. The response surface obtained indicated a maximum at 728 uC for the pyrolysis temperature and at 2696 uC for the atomisation temperature. The proposed method allows silicon determination in naphtha with a detection limit of 15 mg L21 and a characteristic mass of 143 pg. The precision, expressed as relative standard deviation, was 8 and 11.4% for silicon concentrations of 100 and 50 mg L21, respectively. Addition/recovery tests of silicon in several naphtha samples proved that this procedure could be applied satisfactorily for analysis of this matrix. The proposed method has been used for silicon determination in naphtha samples processed at Petrobras (São Francisco do Conde, Bahia, Brazil).
URI: http://www.repositorio.ufba.br/ri/handle/ri/5024
Data do documento: 2004
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
246-249.pdf156,64 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.