dc.description.abstractThe technical, environmental and economic feasibility of cogeneration systems, based on natural gas internal combustion engines and absorption chillers was investigated. Projects that meet the growing demand for diversification of energy supply in Brazil are already well studied, but the alignment between the modern incentive and regulation laws with the technologies available in the market for application in supermarkets are not well understood. The objective of the study was divided into: development of a technical indicator (AT) and an economic indicator (VEO) for a general evaluation of cogeneration projects; application of an environmental indicator; mapping constraints and project requirements with respect to the legislation of qualified cogeneration and energy compensation; electrical and thermal load survey in a case study; modeling of the cogeneration plant to meet the case study; evaluation of the case study using the indicators developed. The results present the best combinations for the implementation of cogeneration systems, through a technical approach, using different absorption chiller models; and an environmental approach, with the emission of CO2 from these systems, compared to the emission of the Brazilian matrix. In the economic aspect, the results show the feasibility of implementing the model in a supermarket, together with the daily projection of energy billing and an investments analysis in three risk scenarios. The model showed that the proposed system is technically and financially viable in all scenarios. In the first scenario, with the system running 14 hours a day, the VEO and NPV were positive, the IRR was 4.4% a.m. and a payback of 3.6 years. In the second scenario, with the model operating 24 hours a day, VEO and NPV remained positive, with the IRR at 6.5% a.m. and a payback of 2.6 years. For the third scenario, with the model being aided by a thermal reservoir to accumulate cold water, all investment indicators remained favorable, with VEO and NPV positive, IRR at 4.2% a.m. and payback at 3.7 years.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Bahiapt_BR
dc.subjectCogeração (energia)pt_BR
dc.subjectMotor de combustão internapt_BR
dc.subjectRefrigeração por absorçãopt_BR
dc.subjectGás naturalpt_BR
dc.subjectGeração distribuída (energia)pt_BR
dc.subjectSupermercadopt_BR
dc.subjectSalvador (BA)pt_BR
dc.subject.otherCogeneration (energy)pt_BR
dc.subject.otherInternal combustion enginept_BR
dc.subject.otherAbsorption chillerpt_BR
dc.subject.otherNatural gaspt_BR
dc.subject.otherDistributed generation (energy)pt_BR
dc.subject.otherSupermarketpt_BR
dc.subject.otherSalvador (BA)pt_BR
dc.titleSistemas de cogeração para pequenas e médias empresas do setor terciáriopt_BR
dc.typeDissertaçãopt_BR
dc.contributor.refereesFerreira, Vitor Pinheiro-
dc.publisher.programPrograma de Pós-Graduação em Engenharia Industrial (PEI) pt_BR
dc.publisher.initialsUFBApt_BR
dc.publisher.countryBrasilpt_BR
dc.subject.cnpqCNPQ::ENGENHARIASpt_BR
dc.contributor.advisor1Torres, Ednildo Andrade-
dc.contributor.advisor2Silva, Julio Augusto Mendes da-
dc.contributor.referee1Torres, Ednildo Andrade-
dc.contributor.referee2Silva, Julio Augusto Mendes da-
dc.contributor.referee3Almeida, Antonio Gabriel Souza-
dc.creator.Latteshttp://lattes.cnpq.br/6404867456336336pt_BR
dc.description.resumoA viabilidade técnica, ambiental e econômica de sistemas de cogeração de energia, baseados em motor alternativo a gás natural e chiller por absorção foi investigada. Projetos que atendam à crescente demanda por diversificação da oferta energética no Brasil já são bem estudados, mas o alinhamento entre as modernas legislações de incentivo e regulação com as tecnologias disponíveis no mercado para aplicação em supermercados não é bem compreendido. O objetivo do estudo foi dividido em: desenvolvimento de um indicador técnico (AT) e um indicador econômico (VEO) para avaliação geral de projetos de cogeração; aplicação de um indicador ambiental; mapeamento das restrições e exigências de projeto no que diz respeito à legislação da cogeração qualificada e compensação de energia; levantamento da carga térmica e elétrica em um estudo de caso; modelagem da planta de cogeração para atender o estudo de caso; avaliação do estudo de caso por meio dos indicadores desenvolvidos. Os resultados apresentam as melhores combinações para implantação de sistemas de cogeração, através de uma abordagem técnica, utilizando diferentes modelos de chiller por absorção; e uma abordagem ambiental, com a emissão de CO2 desses sistemas, comparada com a emissão da matriz brasileira. No quesito econômico, os resultados apresentam a viabilidade de implantação do modelo em um supermercado, junto com a projeção diária do faturamento da energia e uma análise de investimentos em três cenários de risco. O modelo mostrou que o sistema proposto é tecnicamente e financeiramente viável em todos os cenários. No 1º cenário, com o sistema funcionando 14 horas por dia, o VEO e o VPL foram positivos, a TIR ficou em 4,4% a.m. e um payback de 3,6 anos. No 2º cenário, com o modelo operando 24 horas por dia, o VEO e o VPL continuaram positivos, com a TIR em 6,5% a.m. e um payback de 2,6 anos. Para o 3º cenário, com o modelo sendo auxiliado por um reservatório térmico para acumular água gelada, todos os indicadores de investimentos continuaram favoráveis, com VEO e VPL positivos, TIR em 4,2% a.m. e payback de 3,7 anos.pt_BR
dc.publisher.departmentEscola Politécnicapt_BR
dc.type.degreeMestrado Acadêmicopt_BR
Aparece nas coleções:Dissertação (PEI)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Dissertacao Marcos Scaramussa Jr.pdf2,95 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.