Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/20507
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.advisorKorn, Mauro-
dc.contributor.authorLopes, Mariângela Vieira-
dc.creatorLopes, Mariângela Vieira-
dc.date.accessioned2016-09-14T20:43:57Z-
dc.date.available2016-09-14T20:43:57Z-
dc.date.issued2016-09-14-
dc.date.submitted2005-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/20507-
dc.description.abstractNeste trabalho, foram desenvolvidos procedimentos e sistemas automatizados para o controle de qualidade de carnes e produtos cárneos quanto à presença de aditivos (NO2- e NO3-), degradação (evolução de H2S), presença de adulterante (SO3-) e riscos de contaminação pela capacidade sortiva de metais. O desenvolvimento destes procedimentos vem contrapor as metodologias clássicas recomendadas pelos órgãos oficiais brasileiros. Os métodos e procedimentos aqui desenvolvidos obedecem às recomendações da Química Analítica moderna, as quais priorizam precisão, exatidão, sensibilidade, custos operacionais, versatilidade, robustez, rastreabilidade, minimização de resíduos e produtividade analítica. O sistema de analise por injeção em fluxo (FIA), para análise seletora e discriminatória de H2S evoluído pela carne, foi desenvolvido baseado no método do azul de metileno. O emprego da multicomutação, associado à câmara de pervaporação, conferiu versatilidade ao sistema com produtividade analítica de 30 determinações h-1. Paralelo a isto, foi realizada uma avaliação da degradação de carnes empregando a espectroscopia no infravermelho próximo (NIR) para averiguação das condições de conservação de carnes. Os resultados foram concordantes para as duas metodologias (NIR e FIA), sendo possível detectar indícios de deterioração após 30 min de exposição da carne à atmosfera em temperatura ambiente. O desenvolvimento de sistema em fluxo para análise seqüencial de NO2- e NO3-, em produtos cárneos, utilizando câmara de tubos concêntricos (CTC) foi baseado no método de Greiss. A CTC proporcionou a divisão da zona da amostra, facilitando as determinações seqüenciais de NO2- e NO3-. A subzona da amostra que passava pelo tubo central da CTC resultava apenas na determinação do NO2-. A amostra que passava pelo tubo externo (coroa) da CTC, percolava grãos de cádmio coperizado, resultando na redução do NO3- existente à NO2-. Este sistema ofereceu boa sensibilidade para a quantificação dos analitos, apresentando limites de detecção de 0,018 e 0,036 mg L-1 para NO2- e NO3-, respectivamente. O procedimento proposto atingiu produtividade analítica de 120 determinações h-1. O desenvolvimento de sistema automatizado em fluxo para análise discriminatória de sulfito em carnes foi baseado no método da p-rosanilina. Foi empregado câmara de permeação gasosa, onde o SO3- presente na amostra, permeava através de membrana de PTFE para a reação com o reagente cromogênico. O sistema foi satisfatório para screening analysis, com produtividade analítica de 12 determinações h-1. A capacidade sortiva de metais pela carne bovina foi também avaliada. Foi avaliado o contato estático da carne com soluções de referência de Cd e Pb, preparadas com água de torneira, a pH 6. Foi empregada válvula multiportas, com oito canais para execução dos experimentos, enquanto que metais foram determinados por ICP OES. Os resultados indicaram um elevado poder sortivo, cerca de 80% para ambos os metais, evidenciando risco potencial de contaminação para as carnes submetidas a práticas inadequadas de abate e comercializaçãopt_BR
dc.description.abstractIn the present work automated systems and procedures to control the quality of meats and meat products had been developed, in concern to the additive presence (NO2- and NO3-), degradation (H2S evolution) and presence of adulterating species (SO32-). Also the metal sorption capacity on meat was evaluated. The development of these methods comes to oppose classical methods recommended by brazilian official agencies. The developed procedures follow the recommendations of the modern Analytical Chemical, which prioritizes the precision, exactness, sensitivity, traceability, robustness, reduced operational costs, lesser production of residue and raised analytical productivity. The flow analysis (FIA) procedure to discriminate H2S in meat sample was developed based on methylene blue method. Multicommutation, associated to gas permeation conferred versatility to the system with analytical throughput of 30 determinations h-1. Parallel to this, the spectroscopy in the near infrared region (NIR) was carried out to evaluate meat degradation. A flow system for sequential NO2- and NO3- analysis in meat products, using concentric tubes chamber (CTC) was based on the Greiss method. The CTC provides the division of sample zone, permitting the sequential analysis. The sample sub zone that passed for the central pipe of the CTC resulted in the determination of the NO2-. The sample that passed through external CCP pipe, percolated the cadmium column, allowing the reduction of the NO3- to NO2-. This system offers sensitivity in the quantification of anilities with detection limits of 0.036 for NO3- and 0.018 mg L-1 for NO2-, reaching 120 determinations h-1. The flow system for the screening analysis of SO32- in meat sample was based on p-rosanilne method. Chamber for gas permeation was employed. The system revealed efficient for screening analysis with analytical throughput of 12 determination h-1. The metal sorption capacity on meat was evaluated. The investigated species comprised Cd and Pb from solutions prepared with tap water at pH 6. In the experimental set, it was employed an eight channels multiport valve in order to prepare part of the samples, while the metal determinations was carried out by using ICP OES technique. The results obtained demonstrated an expressive retention capacity of meat for Cd2+ and Pb2+ ions with percentages ca. 80% (m/m) for both metals, indicating the potential risks related to the consumption of meat submitted to inappropriate conditions of abattoir, handling, storage and commercialization.pt_BR
dc.language.isopt_BRpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCarnept_BR
dc.subjectCarne-Controle de Qualidadept_BR
dc.subjectFIA-Método de Análisept_BR
dc.subjectNitratopt_BR
dc.subjectNitritopt_BR
dc.subjectSulfito-Análise de Substância Carnespt_BR
dc.subjectSulfetopt_BR
dc.subjectSulfitopt_BR
dc.subjectSorção de metaispt_BR
dc.subjectMeatpt_BR
dc.subjectSulphidept_BR
dc.subjectNitritept_BR
dc.subjectNitratept_BR
dc.subjectSulphitept_BR
dc.subjectMetal sorptionpt_BR
dc.titleDesenvolvimento de procedimentos e sistemas automatizados para controle de qualidade de carnes e produtos cárneospt_BR
dc.typeTesept_BR
dc.publisher.departamentInstituto de Químicapt_BR
dc.publisher.programPrograma de Pós Graduação em Químicapt_BR
dc.publisher.initialsIQpt_BR
dc.publisher.countrybrasilpt_BR
dc.subject.cnpqQuímica Analíticapt_BR
Aparece nas coleções:Tese (PPGQUIM)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.