Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/20470
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCampanha, Bruno Pereira-
dc.contributor.authorPozza, Daniel Humberto-
dc.contributor.authorWeber, João Batista Blessmann-
dc.contributor.authorOliveira, Marília Gerhardt de-
dc.creatorCampanha, Bruno Pereira-
dc.creatorPozza, Daniel Humberto-
dc.creatorWeber, João Batista Blessmann-
dc.creatorOliveira, Marília Gerhardt de-
dc.date.accessioned2016-09-14T17:38:56Z-
dc.date.available2016-09-14T17:38:56Z-
dc.date.issued2007-01-
dc.identifier.citationCAMPANHA, B. P. et al. Anchorage evaluation of dental implants irradiated with GaAIAs laser (830nm). R. Ci. méd. biol., Salvador, v. 6, n. 1, p. 32-38, jan./abr. 2007.pt_BR
dc.identifier.issn2236-5222-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/20470-
dc.description.abstractThe aim of the present study was to evaluate titanium implants fixed with free rotation in rabbit’s tibia and irradiated with GaAlAs laser (4.3Joules/daily, 830nm wavelength, 12mW and 51 seconds) using a digital torquimeter. Thirty male rabbits were divided into two groups (Laser and Control) and subdivided according to their death day 15 (L1 and C1), 30 (L2 and C2) and 45 (L3 and C3) after surgery. A digital torquimeter evaluated the torque needed for removing the implants, breaking their union to the bone. The results were submitted to Student’s “t” test and ANOVA test, in order to validate these findings. It was observed an increase on removal torque values of irradiated implants both with 15 and 30 days after surgery, in comparison to control groups. With 45 days, there was no statistically significant difference between the Laser and Control groups values. It was concluded that Laser group showed a higher value in the removal torque when compared to non-irradiated implantspt_BR
dc.language.isopt_BRpt_BR
dc.publisherInstituto de Ciências da Saúde/ Universidade Federal da Bahiapt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://www.portalseer.ufba.br/index.php/cmbio/article/view/4146/3028pt_BR
dc.subjectDental implants.pt_BR
dc.subjectLaser.pt_BR
dc.subjectOsseointegration.pt_BR
dc.titleAnchorage evaluation of dental implants irradiated with GaAIAs laser (830nm)pt_BR
dc.title.alternativeRevista de Ciências Médicas e Biológicaspt_BR
dc.typeArtigo de Periódicopt_BR
dc.description.localpubSalvadorpt_BR
dc.identifier.numberv.6, n.1pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (PPGPIOS)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
4_v.6_1.pdf108,74 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.