Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/16504
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorAguiar, Thaiane Rodrigues-
dc.contributor.authorCasamassa, Cristiane Franco Pinto,-
dc.contributor.authorGobbo, Vanessa Cavalli-
dc.contributor.authorUchôa, Marines Nobre dos Santos-
dc.contributor.authorAmbrosano, Gláucia Maria Bovi-
dc.contributor.authorCanedo, Paula Mathias de Morais-
dc.contributor.authorGiannini, Marcelo-
dc.creatorAguiar, Thaiane Rodrigues-
dc.creatorCasamassa, Cristiane Franco Pinto,-
dc.creatorGobbo, Vanessa Cavalli-
dc.creatorUchôa, Marines Nobre dos Santos-
dc.creatorAmbrosano, Gláucia Maria Bovi-
dc.creatorCanedo, Paula Mathias de Morais-
dc.creatorGiannini, Marcelo-
dc.date.accessioned2014-11-04T15:05:58Z-
dc.date.available2014-11-04T15:05:58Z-
dc.date.issued2012-
dc.identifier.issn0361-7734-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/16504-
dc.descriptionp. 63-70pt_BR
dc.description.abstractThis study evaluated the effects of curing modes and storage conditions on fluoride release of resin cements. In phase 1, the cumulative fluoride release rate from samples of the resin cements (Panavia F 2.0, RelyX Unicem, MaxCem, and BisCem) was quantified after 15 days storage in water (n=4). In phase 2, the fluoride release profiles from the same materials were analyzed during pH cycling (n=4). In this second phase, fluoride was measured at specific times (one, two, three, five, eight, and 15 days). Disk-shaped specimens were prepared (10 mm × 0.5 mm), and the materials were either light activated or allowed to autopolymerize. For both phases, the fluoride release was measured using a fluoride ion-specific electrode. The fluoride release in water was not affected by the curing mode of RelyX Unicem and Maxcem resin cements. Panavia F. 2.0 and BisCem resin cements, either light cured or autopolymerized modes, released higher amounts of fluoride in water than the other self-adhesive cements. In phase 2, the concentration of fluoride released decreased from the first day of pH cycling until the 15th day for all resin cements, for both curing modes, regardless of the storage solution used (demineralizing/remineralizing). The fluoride release rate during pH cycling by Panavia F 2.0 and MaxCem was not affected by the curing mode. The effect of the curing mode on fluoride ion release in water or during pH cycling was product dependent.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org.ez10.periodicos.capes.gov.br/10.2341/10-328-Lpt_BR
dc.subjectResin Cementspt_BR
dc.subjectFluoridept_BR
dc.subjectDentistrypt_BR
dc.titleInfluence of the Curing Mode on Fluoride Ion Release of Self-adhesive Resin Luting Cements in Water or During pH-Cycling Regimenpt_BR
dc.title.alternativeOperative Dentistrypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 37, n. 1pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
T. R Aguiar.pdf500,87 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.