Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/16378
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBastos, Luana Costa-
dc.contributor.authorCampos, Paulo Sérgio Flores-
dc.contributor.authorPerez, Flávia Maria de Moraes Ramos-
dc.contributor.authorPontual, Andréa dos Anjos-
dc.contributor.authorAlmeida, Solange Maria de-
dc.creatorBastos, Luana Costa-
dc.creatorCampos, Paulo Sérgio Flores-
dc.creatorPerez, Flávia Maria de Moraes Ramos-
dc.creatorPontual, Andréa dos Anjos-
dc.creatorAlmeida, Solange Maria de-
dc.date.accessioned2014-10-10T15:07:20Z-
dc.date.available2014-10-10T15:07:20Z-
dc.date.issued2013-
dc.identifier.issn1806-8324-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/16378-
dc.descriptionp. 503-509pt_BR
dc.description.abstractThis study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and/or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar's test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1590/S1806-83242013000600010pt_BR
dc.subjectMandibular Condylept_BR
dc.subjectBone Diseasespt_BR
dc.subjectCone-Beam Computed Tomographypt_BR
dc.subjectImage Enhancementpt_BR
dc.titleEvaluation of condyle defects using different reconstruction protocols of cone-beam computed tomographypt_BR
dc.title.alternativeBrazilian Oral Researchpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 27, n. 6pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.