Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/16060
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorOriá, Arianne Pontes-
dc.contributor.authorDórea Neto, Francisco de Assis-
dc.contributor.authorSantos, Luís Alberto dos-
dc.contributor.authorPiza, Evandro de Toledo-
dc.contributor.authorBrunelli, Adriana Torrecilhas Jorge-
dc.contributor.authorNishimori, Celina Tie-
dc.contributor.authorSouza, Ana Letícia Groszewicz de-
dc.contributor.authorGomes Junior, Deusdete Conceição-
dc.contributor.authorLaus, José Luiz-
dc.creatorOriá, Arianne Pontes-
dc.creatorDórea Neto, Francisco de Assis-
dc.creatorSantos, Luís Alberto dos-
dc.creatorPiza, Evandro de Toledo-
dc.creatorBrunelli, Adriana Torrecilhas Jorge-
dc.creatorNishimori, Celina Tie-
dc.creatorSouza, Ana Letícia Groszewicz de-
dc.creatorGomes Junior, Deusdete Conceição-
dc.creatorLaus, José Luiz-
dc.date.accessioned2014-09-11T17:49:26Z-
dc.date.available2014-09-11T17:49:26Z-
dc.date.issued2012-
dc.identifier.issn0034-737X,-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/16060-
dc.descriptionp. 452-457pt_BR
dc.description.abstractSpheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1590/S0034-737X2012000400004pt_BR
dc.subjectIntraocular prosthesispt_BR
dc.subjectEnucleationpt_BR
dc.subjectEviscerationpt_BR
dc.subjectPrótese intraocularpt_BR
dc.subjectEnucleaçãopt_BR
dc.subjectEvisceraçãopt_BR
dc.titleEvaluation of polymethylmethacrylate as ocular implant in rabbits subjected to eviscerationpt_BR
dc.title.alternativeRevista Cerespt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 59, n. 4pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (EMV)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.