dc.description.abstractA procedure for separation of platinum from ferrous matrices was developed using platinum sorption as chloride complexes on polyurethane foam, with subsequent determination by inductively coupled plasma optical emission spectrometry (ICP OES). The procedure was optimized using a two-level full factorial and Doehlert designs. Four variables (foam mass, shaking time, stannous chloride concentration and hydrochloric acid concentration) were regarded as factors in the extraction optimization. Results of the two-level full factorial design, 24 with 16 runs based on Analysis of Variance (ANOVA) showed that only two factors (foam mass and shaking time) are statistically significant. Doehlert design was applied in order to determine the optimum conditions for platinum separation. The proposed procedure allowed platinum determination with a detection limit of 66 μg L−1 and a precision, calculated as relative standard deviation (RSD), of 1.2% in a set of 10 measurements for a platinum concentration of 10.0 μg L−1. The studied procedure was applied to platinum determination in several ferrous matrices (iron ores, pure iron and catalysts). Spike tests on iron ores and pure iron showed good performance in platinum recovery. The good accuracy of the proposed procedure was confirmed by analysis of an ore platinum standard reference material (SARM-7).pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/ 10.1039/C2AY05672Kpt_BR
dc.titleFactorial and Doehlert designs in the optimization of a separation procedure using polyurethane foam as a solid phase extractant for platinum determination in ferrous matrices using inductively coupled plasma optical emission spectroscopypt_BR
dc.title.alternativeAnalytical Methodspt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 4, n. 2pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Neyla Margarida Lopo de Araújo.pdf305,86 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.