Use este identificador para citar ou linkar para este item:
https://repositorio.ufba.br/handle/ri/14923
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Santos, Klécia M. | - |
dc.contributor.author | Cortez, Juliana | - |
dc.contributor.author | Raimundo Junior, Ivo Milton | - |
dc.contributor.author | Pasquini, Celio | - |
dc.contributor.author | Boa Morte, Elane Santos da | - |
dc.contributor.author | Korn, Maria das Graças Andrade | - |
dc.creator | Santos, Klécia M. | - |
dc.creator | Cortez, Juliana | - |
dc.creator | Raimundo Junior, Ivo Milton | - |
dc.creator | Pasquini, Celio | - |
dc.creator | Boa Morte, Elane Santos da | - |
dc.creator | Korn, Maria das Graças Andrade | - |
dc.date.accessioned | 2014-05-06T15:12:17Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 0026-265X | - |
dc.identifier.uri | http://repositorio.ufba.br/ri/handle/ri/14923 | - |
dc.description | Texto completo: acesso restrito. p. 435–438 | pt_BR |
dc.description.abstract | A plasticised PVC membrane containing pyrochatecol violet as complexing reagent has been used to extract and pre-concentrate Cu2 + ions from aqueous solution, aiming at their determination by Laser Induced Breakdown Spectroscopy. The membrane was prepared from a THF cocktail solution on a cellulose acetate support by the dip-coating technique, providing a homogeneous distribution of the complexing reagent and a thickness of 3 μm. The extraction was straightforwardly performed by immersing the membrane in the Cu2 + sample solution buffered at pH 6.0 with sodium acetate. The extraction time defined the working analytical range (from μg L− 1 to mg L− 1) and a 50-min extraction provided a detection limit of 15 μg L− 1 for Cu2 + ions. The membrane is stable for at least 2 months when stored in a desiccator, allowing in-field extractions, that avoid sampling, storage and transport of the aqueous sample to the laboratory. | pt_BR |
dc.language.iso | en | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.source | http://dx.doi.org/10.1016/j.microc.2013.05.013 | pt_BR |
dc.subject | LIBS | pt_BR |
dc.subject | PVC membrane | pt_BR |
dc.subject | Cu2 + ions | pt_BR |
dc.subject | Liquid–solid extraction | pt_BR |
dc.subject | Pre-concentration | pt_BR |
dc.title | An assessment of the applicability of the use of a plasticised PVC membrane containing pyrochatecol violet complexing reagent for the determination of Cu2 + ions in aqueous solutions by LIBS | pt_BR |
dc.title.alternative | Microchemical Journal | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.identifier.number | v. 110 | pt_BR |
dc.embargo.liftdate | 10000-01-01 | - |
Aparece nas coleções: | Artigo Publicado em Periódico (Química) |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
1-s2.0-S0026265X13001100-main.pdf | 451,42 kB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.