Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14882
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorShaltout, Abdallah A.-
dc.contributor.authorWelz, Bernhard-
dc.contributor.authorCastilho, Ivan N. B.-
dc.creatorShaltout, Abdallah A.-
dc.creatorWelz, Bernhard-
dc.creatorCastilho, Ivan N. B.-
dc.date.accessioned2014-04-29T16:38:44Z-
dc.date.issued2013-
dc.identifier.issn1352-2310-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14882-
dc.descriptionTexto completo: acesso restrito. p. 18–24pt_BR
dc.description.abstractThe present work describes the determination of Sb and Mo in dust deposited on tree leaves using direct solid sample analysis. Nineteen air particulate samples were collected from different districts of Cairo and surrounding cities. Since some samples have been taken from places less exposed to the pollution factors, the present study allows the comparison of air quality between high and low polluted areas. High-resolution continuum source graphite furnace atomic absorption spectrometry has been investigated, using direct solid sample analysis. The optimum pyrolysis and atomization temperatures for Sb were found to be 800 °C and 1900 °C, and 1200 °C and 2650 °C, respectively for Mo. The limits of detection and quantification for both, Sb and Mo, were 15 μg g−1 and 50 ng g−1, respectively. The characteristic mass at was found to be m0 = 38 pg for Sb (217.582 nm) and m0 = 28 pg for Mo (313.259 nm). The results obtained for three certified reference materials of urban particulate matter confirmed the validity of the investigated method. The content of Sb varied between 213 ± 1.3 μg g−1 and 1117 ± 230 μg g−1 with an average of 667 ± 339 μg g−1. On the other hand, the Mo content varied from 113 ± 2.3 μg g−1 to 361 ± 51 μg g−1 and its average value equals 190 ± 62 μg g−1.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.atmosenv.2013.08.049pt_BR
dc.subjectAir pollutionpt_BR
dc.subjectSbpt_BR
dc.subjectMopt_BR
dc.subjectDirect solid sample analysispt_BR
dc.subjectHigh-resolution continuum source graphite furnace atomic absorption spectrometrypt_BR
dc.titleDeterminations of Sb and Mo in Cairo's dust using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysispt_BR
dc.title.alternativeAtmospheric Environmentpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 81pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S1352231013006699-main.pdf1,46 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.