Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14828
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorQuintella, Cristina Maria Assis Lopes Tavares da Mata Hermida-
dc.contributor.authorMeira, Marilena-
dc.contributor.authorSilva, Weidson Leal-
dc.contributor.authorDiógenes Filho, Rogério Guerra-
dc.contributor.authorAraújo, André Luiz Carneiro de-
dc.contributor.authorSilva Júnior, Elias T.-
dc.contributor.authorSales, Lindolfo J. O.-
dc.creatorQuintella, Cristina Maria Assis Lopes Tavares da Mata Hermida-
dc.creatorMeira, Marilena-
dc.creatorSilva, Weidson Leal-
dc.creatorDiógenes Filho, Rogério Guerra-
dc.creatorAraújo, André Luiz Carneiro de-
dc.creatorSilva Júnior, Elias T.-
dc.creatorSales, Lindolfo J. O.-
dc.date.accessioned2014-04-22T12:36:40Z-
dc.date.issued2013-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14828-
dc.descriptionTexto completo: acesso restrito. p. 263–267pt_BR
dc.description.abstractPower transformers are essential for a functioning electrical system and therefore require special attention by maintenance programs because a fault can harm both the company and society. The temperature inside a power transformer and the dissolved gases, which are primarily composed of acetylene, are the two main parameters monitored when detecting faults. This paper describes the development of a device for analyzing the acetylene content in insulating oil using spectrofluorimetry. Using this device introduces a new methodology for the maintaining and operating power transformers. The prototype is currently operating in a substation. The results presented by this system were satisfactory; when compared to chromatographic data, the errors did not exceed 15%. This prototype may be used to confirm the quality of an insulating oil sample to detect faults in power transformers.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.talanta.2013.08.018pt_BR
dc.subjectInsulating oilpt_BR
dc.subjectPower transformerpt_BR
dc.subjectAcetylenept_BR
dc.subjectOptical sensorpt_BR
dc.titleDevelopment of a spectrofluorimetry-based device for determining the acetylene content in the oils of power transformerspt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 117pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.