Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14578
Tipo: Artigo de Periódico
Título: Hydride generation in-atomizer collection atomic absorption spectrometry for the determination of antimony in acetic acid leachates from pewter cups
Título(s) alternativo(s): Talanta
Autor(es): Vale, Maria Goreti R.
Dessuy, Morgana B.
Kratzer, Jan
Welz, Bernhard
Dědina, Jiří
Autor(es): Vale, Maria Goreti R.
Dessuy, Morgana B.
Kratzer, Jan
Welz, Bernhard
Dědina, Jiří
Abstract: Antimony is one of the constituents of pewter, an alloy composed of a minimum of 90% tin with the balance being made up with copper, antimony and perhaps some bismuth. A method has been developed to determine Sb in acetic acid leachates from pewter cups. The employed instrumentation, an atomic absorption spectrometer, equipped with a quartz trap-and-atomizer device, is simple and relatively inexpensive with low running costs. Interferences due to the presence of tin and ways to control them were investigated in detail. The applied approach made possible to overcome potentially serious interference of Sn leached from the cup material (which was shown to take place in the atomizer), by a combination of (i) high concentration of HCl, which decreases the efficiency of stannane generation and (ii) in-atomizer collection. The resulting Sn tolerance limit was between 10 and 20 mg L−1. The advantages of the in-atomizer collection are a lower tin interference in the atomizer, and a much better limit of detection (LOD), which makes possible reducing the atomization interference further by working with more diluted sample solutions. Besides the Sn interference, an interference of an unknown volatile compound transported to the atomizer together with stibine was identified in the measured sample solutions. This interference could be controlled using the analyte addition technique. The applicability of the method was tested on solutions containing a wide range of interferents leached from the pewter cups, obtained at leaching times between 1 and 24 h. The LOD in the sample solutions was found to be 0.03 μg L−1 Sb.
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/14578
Data do documento: 2011
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Maria Goreti.pdf315,44 kBAdobe PDFVisualizar/Abrir