dc.contributor.authorSousa, Clarivaldo Santos de-
dc.contributor.authorNascentes, Clésia C.-
dc.contributor.authorKorn, Mauro-
dc.contributor.authorArruda, Marco Aurélio Zezzi-
dc.creatorSousa, Clarivaldo Santos de-
dc.creatorNascentes, Clésia C.-
dc.creatorKorn, Mauro-
dc.creatorArruda, Marco Aurélio Zezzi-
dc.date.accessioned2014-02-03T16:58:16Z-
dc.date.available2014-02-03T16:58:16Z-
dc.date.issued2001-
dc.identifier.issn0103-5053-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14529-
dc.descriptionp. 57-63pt_BR
dc.description.abstractOptimisation conditions for obtaining maximum cavitation intensity in ultrasonic baths are proposed using a simple and fast method. Parameters such as water volume, temperature, detergent concentration, horizontal and vertical positions, number of tubes in the bath, sonication time and bath water substitution were studied. The results obtained for both baths studied (Neytech and Cole-Parmer) lead to the following conditions for maximum cavitation intensity: 1 L of water at room temperature, 0.2 % (v/v) of detergent, central position on the bottom of the tank. Only one tube at a time should be used inside the bath during the ultrasound application. The cavitation intensity was linear with the sonication time up to 10 minutes and the water substitution during the sonication improved reproducibility. This system using continuous water change makes possible the sonication of 6 consecutive samples, without changes in the water volume.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1590/S0103-50532001000100008pt_BR
dc.subjectUltrasonic bathpt_BR
dc.subjectAnalytical applicationpt_BR
dc.subjectCavitationpt_BR
dc.subjectIodinept_BR
dc.subjectHydrogenpt_BR
dc.titleUse of Ultrasonic Baths for Analytical Applications: A New Approach for Optimisation Conditionspt_BR
dc.title.alternativeJournal of the Brazilian Chemical Societypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 182, n. 1pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Clarivaldo S. Sousa.pdf130,64 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.