Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14467
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBorges, Daniel L. G.-
dc.contributor.authorWelz, Bernhard-
dc.contributor.authorCurtius, Adilson José-
dc.creatorBorges, Daniel L. G.-
dc.creatorWelz, Bernhard-
dc.creatorCurtius, Adilson José-
dc.date.accessioned2014-01-24T13:02:14Z-
dc.date.issued2007-
dc.identifier.issn0026-3672-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14467-
dc.descriptionTexto completo: acesso restrito. p. 19-26pt_BR
dc.description.abstractA method was developed for the determination of As, Cd, Pb and Tl by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) with slurry sample introduction using certified reference coal samples. The 75As, 111Cd, 208Pb and 205Tl isotopes were monitored, considering the lower probabilities of these isotopes in suffering interferences. The carrier and modifier effect of Ru added in solution was evaluated, demonstrating that sensitivity for all elements is considerably improved by the addition of 15 µg of Ru to each individual measurement. This confirms its ability to act as a physical carrier particularly for the analytes in aqueous solution. Pyrolysis and vaporization temperatures of 500 and 2500 °C, respectively, were selected after optimization for aqueous solutions and for coal slurries. Similarly, the carrier gas flow rate was optimized as 1.1 L min−1. After optimization of the operational parameters, the determination of the four elements in six certified reference coal samples was carried out by external calibration against aqueous standards in 5% v/v HNO3, resulting in good agreement between the certified or given values and the determined ones. For Tl, due to the absence of certified values, a comparison was established considering previously published data using solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry. Detection limits (µg g−1) of 0.1, 0.004, 0.045 and 0.001 were achieved for As, Cd, Pb and Tl, respectively, and the precision was typically better than 10%.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1007/s00604-006-0730-7pt_BR
dc.subjectElectrothermal vaporization inductively coupled plasma mass spectrometrypt_BR
dc.subjectCoalpt_BR
dc.subjectSlurry samplingpt_BR
dc.subjectRuthenium modifierpt_BR
dc.subjectAerosol carrierpt_BR
dc.titleDetermination of As, Cd, Pb and Tl in coal by electrothermal vaporization inductively coupled plasma mass spectrometry using slurry sampling and external calibration against aqueous standardspt_BR
dc.title.alternativeMicrochimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 159, n. 1-2pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
art%3A10.1007%2Fs00604-006-0730-7.pdf150,99 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.