Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/14398
metadata.dc.type: Artigo de Periódico
Título : Feasibility of using direct determination of cadmium and lead in fresh meat by electrothermal atomic absorption spectrometry for screening purposes
Otros títulos : Spectrochimica Acta Part B: Atomic Spectroscopy
Autor : Damin, Isabel Cristina Ferreira
Silva, Márcia M.
Vale, Maria Goreti R.
Welz, Bernhard
metadata.dc.creator: Damin, Isabel Cristina Ferreira
Silva, Márcia M.
Vale, Maria Goreti R.
Welz, Bernhard
Resumen : A method for the direct determination of cadmium and lead in fresh meat for screening purposes is proposed using electrothermal atomic absorption spectrometry. The fresh meat samples were homogenized, weighed directly onto solid sampling platforms and introduced into a transversely heated solid sampling graphite tube. The main challenges associated with this procedure, such as weighing errors and optimization of the temperature program were investigated in detail. Calibration was performed against aqueous standards and two modifiers were investigated: 0.05% Pd + 0.03% Mg + 0.05% Triton X-100 and 0.01% Pd + 10% NH4NO3 + 0.05% Triton X-100. The former one is recommended due to the higher pyrolysis temperature obtained for cadmium and the better limits of detection of 1.9 μg kg− 1 for lead and 0.13 μg kg− 1 for cadmium, based on 10 mg of sample mass. The results obtained for cadmium and lead in two certified reference materials were statistically not different from the certified values on a 95% confidence level, indicating that calibration against aqueous standards is suitable for this application. In order to evaluate weighing errors the fresh samples were dried (at 60 °C) to constant weight; the results obtained with fresh and dried samples were in agreement, taking the loss of weight into consideration for the latter ones. The average relative standard deviation of 14% is in concordance with the results of others using fresh meat. Comparison with the digestion method adopted by the Brazilian Ministry of Agriculture shows no significant differences between the results at the 95% confidence level. This study shows that direct analysis of fresh meet can be applied as a rapid routine screening procedure for residue control in products of animal origin, helping the implementation and maintenance of sanitary control.
Palabras clave : Lead
Cadmium
Fresh meat
Screening analysis
Electrothermal atomic absorption spectrometry
metadata.dc.rights: Acesso Aberto
URI : http://repositorio.ufba.br/ri/handle/ri/14398
Fecha de publicación : 2007
Aparece en las colecciones: Artigo Publicado em Periódico (Química)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
1-s2.0-S0584854707001565-main.pdf300,96 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.