Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14335
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorFerreira, Hadla S.-
dc.contributor.authorJesus, Robson M. de-
dc.contributor.authorSantos, João Victor da Silva-
dc.contributor.authorBrandão, Geovani Cardoso-
dc.contributor.authorSouza, Anderson Santos-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorFerreira, Hadla S.-
dc.creatorJesus, Robson M. de-
dc.creatorSantos, João Victor da Silva-
dc.creatorBrandão, Geovani Cardoso-
dc.creatorSouza, Anderson Santos-
dc.date.accessioned2014-01-13T14:34:20Z-
dc.date.issued2007-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14335-
dc.descriptionTexto completo: acesso restrito. p. 89-93pt_BR
dc.description.abstractIn this paper, we proposed a procedure for the determination of iron(II) and total iron in wine samples employing molecular absorption spectrophotometry. The ligand used is 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) and the chromogenic reaction in absence or presence of ascorbic acid (reducing agent) allows the determination of iron(II) or total iron, respectively. The optimization step was performed using a multivariate technique (Box Behnken design) involving the factors pH, acid ascorbic concentration and reaction time. The method allows the determination of iron(II) and iron(III) in wine samples, with limits of detection and quantification 0.22 and 0.72 μg L−1, respectively. The precision expressed as relative standard deviation (R.S.D.) was 1.43 and 0.56% (both, n = 11) for content of iron(II) in wine samples of 1.68 and 4.65 mg L−1, and 1.66 and 0.87% (both, n = 11) for content of total iron in wine samples of 1.72 and 5.48 mg L−1. This method was applied for determination of iron(II) and total iron in six different wine samples. In these, the iron(II) content varied from 0.76 to 4.65 mg L−1 and from 1.01 to 5.48 mg L−1 for total iron. The results obtained in the determination of total iron by Br-PADAP method were compared with those that were performed after complete acid digestion in open system and determination of total iron employing FAAS. The method of regression linear was used for comparison of these results and demonstrated that there is no significant difference between the results obtained with these two procedures.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.aca.2007.09.002pt_BR
dc.subjectSpeciation analysispt_BR
dc.subjectIron(II) determinationpt_BR
dc.subjectTotal iron determinationpt_BR
dc.subjectWine samplespt_BR
dc.subjectBox Behnken designpt_BR
dc.titleDevelopment of method for the speciation of inorganic iron in wine samplespt_BR
dc.title.alternativeAnalytica Chimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 602, n. 1pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.