Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/14138
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCerutti, S.-
dc.contributor.authorSalonia, J. A.-
dc.contributor.authorOlsina, R. A.-
dc.contributor.authorMartinez, L. D.-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCerutti, S.-
dc.creatorSalonia, J. A.-
dc.creatorOlsina, R. A.-
dc.creatorMartinez, L. D.-
dc.date.accessioned2013-12-13T12:04:49Z-
dc.date.issued2004-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/14138-
dc.descriptionTexto completo: acesso restrito. p. 1077–1082pt_BR
dc.description.abstractA system for on-line preconcentration and determination of platinum by ultrasonic nebulization (USN) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) was studied. It is based on the chemical sorption of platinum on a column packed with polyurethane foam loaded with thiocyanate reagent. The optimization step was carried out using two level full factorial design. Three variables (pH, loading flow rate (LFR) and eluent concentration) were regarded as factors in the optimization. Results of the two level factorial design 23 with three replicates of the central point for platinum preconcentration, based on the variance analysis (ANOVA), demonstrated that the factors and their interactions are not statistically significant. The proposed procedure allowed the determination of platinum with a detection limit of 0.28 μg l−1. The precision for 10 replicate determinations at 10.0 μg l−1 Pt level was 3.8% relative standard deviation (R.S.D.), calculated from the peak heights obtained. A total enhancement factor of 100 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 10 for preconcentration). A sampling frequency of 50 samples per hour was obtained. The effect of other ions in concentrations agreeing with water samples was studied. The addition/recovery experiments in the samples analyzed demonstrated the accuracy and applicability of the system developed for platinum determination in spiked water samples.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org.ez10.periodicos.capes.gov.br/10.1016/j.talanta.2004.01.016pt_BR
dc.subjectOn-line preconcentrationpt_BR
dc.subjectFactorial designpt_BR
dc.subjectPlatinumpt_BR
dc.subjectPolyurethane foampt_BR
dc.subjectICP-OESpt_BR
dc.titleFactorial design for multivariate optimization of an on-line preconcentration system for platinum determination by ultrasonic nebulization coupled to inductively coupled plasma optical emission spectrometrypt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 63, n. 4pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
S.L.C Ferreira.pdf129,41 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.