Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/13825
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorRossi, Marcelle-
dc.contributor.authorDuarte, Luis Rogério-
dc.contributor.authorMendonça, Robson-
dc.contributor.authorFernandes, Atson Carlos de Souza-
dc.creatorRossi, Marcelle-
dc.creatorDuarte, Luis Rogério-
dc.creatorMendonça, Robson-
dc.creatorFernandes, Atson Carlos de Souza-
dc.date.accessioned2013-11-20T19:46:41Z-
dc.date.issued2008-
dc.identifier.issn1523-0899-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/13825-
dc.descriptionTexto completo: acesso restrito. p. 271-275pt_BR
dc.description.abstractPurpose: The purpose of this study was to obtain anatomical information for installing four zygomatic implants, by measurements of maxillae and zygomata. Materials and Methods: Linear and angular measurements were obtained from the maxillae and zygomata of 40 dry skulls. Results: Based on mean and standard deviation values, the installation angle of the additional implant in the four zygoma technique was between 25° and 47°, and that of the conventional zygomatic implant was between 39° and 62°. The distance between the alveolar crest in the canine region and the lateral margin of the orbital socket was 53.42 mm, and between the alveolar crest in the premolar region and the area closest to the lateral margin of the orbital socket was 42.47 mm. Conclusions: When the angle of installation of the additional implant is less than 25° and that of the conventional zygomatic implant is less than 39°, perforation of the maxilla, zygoma, or the infratemporal fossa must be avoided. When the angle of installation of an additional implant is greater than 47° and that of the conventional zygomatic implant is greater than 62°, perforation of the orbital floor must be avoided. The length of an additional implant was greater than the length of a conventional zygomatic implant, and should be measured prior to drilling, because the greatest value found for this distance was 61.94 mm, while the maximum length of the zygomatic implants currently available on the market is 52.5 mm.pt_BR
dc.language.isopt_BRpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1111/j.1708-8208.2008.00091.xpt_BR
dc.subjectAnatomypt_BR
dc.subjectAtrophic maxillaept_BR
dc.subjectZygomatic bonept_BR
dc.subjectZygomatic implantspt_BR
dc.titleAnatomical bases for the insertion of zygomatic implantspt_BR
dc.title.alternativeClinical Implant Dentistry and Related Researchpt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 10, n. 4pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Medicina)