Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/13144
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.contributor.authorBrandão, Geovani Cardoso-
dc.contributor.authorPortugal, Lindomar Andrade-
dc.contributor.authorDavid, Jorge Mauricio-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.creatorSantos, Walter Nei Lopes dos-
dc.creatorBrandão, Geovani Cardoso-
dc.creatorPortugal, Lindomar Andrade-
dc.creatorDavid, Jorge Mauricio-
dc.creatorFerreira, Sergio Luis Costa-
dc.date.accessioned2013-10-08T15:18:26Z-
dc.date.issued2009-
dc.identifier.issn0584-8547-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/13144-
dc.descriptionTexto completo: acesso restrito. p. 601–604pt_BR
dc.description.abstractThis paper proposes the use of photo-oxidation with UV radiation/H2O2 as sample pretreatment for the determination of iron and manganese in wines by flame atomic absorption spectrometry (FAAS). The optimization involved the study of the following variables: pH and concentration of buffer solution, concentrated hydrogen peroxide volume and irradiation time. The evaluation of sample degradation was monitored by measuring the absorbance at the maximum wavelength of red wine (530 nm). Using the experimental conditions established during the optimization (irradiation time of 30 min, oxidant volume of 2.5 mL, pH 10, and a buffer concentration of 0.15 mol L− 1), this procedure allows the determination of iron and manganese with limits of detection of 30 and 22 μg L− 1, respectively, for a 5 mL volume of digested sample. The precision levels, expressed as relative standard deviation (RSD), were 2.8% and 0.65% for iron and 2.7% and 0.54% for manganese for concentrations of 0.5 and 2.0 mg L− 1, respectively. Addition/recovery tests for evaluation of the accuracy were in the ranges of 90%–111% and 95%–107% for iron and manganese, respectively. This digestion procedure has been applied for the determination of iron and manganese in six wine samples. The concentrations varied from 1.58 to 2.77 mg L− 1 for iron and from 1.30 to 1.91 mg L− 1 for manganese. The results were compared with those obtained by an acid digestion procedure and determination of the elements by FAAS. There was no significant difference between the results obtained by the two methods based on a paired t-test (at 95% confidence level).pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.sab.2009.04.012pt_BR
dc.subjectPhoto-oxidation procedurept_BR
dc.subjectUV radiation/H2O2pt_BR
dc.subjectSample decompositionpt_BR
dc.subjectWine samplespt_BR
dc.subjectMetal determinationpt_BR
dc.subjectFAASpt_BR
dc.titleA photo-oxidation procedure using UV radiation/H2O2 for decomposition of wine samples: determination of iron and manganese content by flame atomic absorption spectrometrypt_BR
dc.title.alternativeSpectrochimica Acta Part B: Atomic Spectroscopypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 64, n. 6pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.