Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/12165
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorDias, Fábio de Souza-
dc.contributor.authorBonsucesso, Josemário Santana-
dc.contributor.authorAlves, Lucylia Suzart-
dc.contributor.authorSilva Filho, Domingos Correia da-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.creatorDias, Fábio de Souza-
dc.creatorBonsucesso, Josemário Santana-
dc.creatorAlves, Lucylia Suzart-
dc.creatorSilva Filho, Domingos Correia da-
dc.creatorCosta, Antonio Celso Spinola-
dc.creatorSantos, Walter Nei Lopes dos-
dc.date.accessioned2013-07-10T18:43:10Z-
dc.date.available2013-07-10T18:43:10Z-
dc.date.issued2013-
dc.identifier.issn0026-265X-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/12165-
dc.descriptionTexto completo. Acesso restrito. p. 363–367pt_BR
dc.description.abstractIn the present work, a minicolumn of sisal fiber loaded with tiazolylazo-Resorsinol (TAR) is proposed a preconcentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. In the optimizationwas first of all a full factorial design of two levels (24)was used for preliminary evaluation of four factors, involving the variables: sampling flow rate, elution flow rate, buffer concentration and pH. This design has showed that, for the studied levels, buffer concentration and pH are significant factors. Using the established experimental conditions in the optimization step of: pH 7.0, buffer concentration of 0.009 mol L−1 for elution utilized HCl at 2.0 mol L−1, this system allows the determination of cadmium with a detection limit (LD) (3σ/S) of 0.05 μg L−1 and a quantification limit (LQ) (10σ/S) of 0.17 μg L−1, precision expressed as a relative standard deviation (R.S.D.) of 2.9 and 3.4% for a cadmium concentration of 10.0 and 20.0 μg L−1, respectively, and a preconcentration factor of 30 for a sample volume of 50.0 mL. The accuracy was confirmed by cadmium with spike tests with recuperations varying from 92% to 103%, procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. From the five samples analyzed, the achieved concentrations varied from 0.10 to 0.54 μg L−1.pt_BR
dc.language.isoenpt_BR
dc.publisherMicrochemical Journalpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.microc.2012.01.018pt_BR
dc.subjectSisal fiberpt_BR
dc.subjectPreconcentrationpt_BR
dc.subjectCadmiumpt_BR
dc.subjectTARpt_BR
dc.titleDevelopment and optimization of analytical method for the determination of cadmium from mineral water samples by off-line solid phase extraction system using sisal fiber loaded TAR by FAASpt_BR
dc.title.alternativeMicrochemical Journalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.description.localpubSalvadorpt_BR
dc.identifier.numberv. 106pt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
2222222222222222.pdf461,2 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.