Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.ufba.br/handle/ri/14335
metadata.dc.type: Artigo de Periódico
Título : Development of method for the speciation of inorganic iron in wine samples
Otros títulos : Analytica Chimica Acta
Autor : Ferreira, Sergio Luis Costa
Ferreira, Hadla S.
Jesus, Robson M. de
Santos, João Victor da Silva
Brandão, Geovani Cardoso
Souza, Anderson Santos
metadata.dc.creator: Ferreira, Sergio Luis Costa
Ferreira, Hadla S.
Jesus, Robson M. de
Santos, João Victor da Silva
Brandão, Geovani Cardoso
Souza, Anderson Santos
Resumen : In this paper, we proposed a procedure for the determination of iron(II) and total iron in wine samples employing molecular absorption spectrophotometry. The ligand used is 2-(5-bromo-2-pyridylazo)-5-(diethylamino)-phenol (Br-PADAP) and the chromogenic reaction in absence or presence of ascorbic acid (reducing agent) allows the determination of iron(II) or total iron, respectively. The optimization step was performed using a multivariate technique (Box Behnken design) involving the factors pH, acid ascorbic concentration and reaction time. The method allows the determination of iron(II) and iron(III) in wine samples, with limits of detection and quantification 0.22 and 0.72 μg L−1, respectively. The precision expressed as relative standard deviation (R.S.D.) was 1.43 and 0.56% (both, n = 11) for content of iron(II) in wine samples of 1.68 and 4.65 mg L−1, and 1.66 and 0.87% (both, n = 11) for content of total iron in wine samples of 1.72 and 5.48 mg L−1. This method was applied for determination of iron(II) and total iron in six different wine samples. In these, the iron(II) content varied from 0.76 to 4.65 mg L−1 and from 1.01 to 5.48 mg L−1 for total iron. The results obtained in the determination of total iron by Br-PADAP method were compared with those that were performed after complete acid digestion in open system and determination of total iron employing FAAS. The method of regression linear was used for comparison of these results and demonstrated that there is no significant difference between the results obtained with these two procedures.
Palabras clave : Speciation analysis
Iron(II) determination
Total iron determination
Wine samples
Box Behnken design
metadata.dc.rights: Acesso Aberto
URI : http://repositorio.ufba.br/ri/handle/ri/14335
Fecha de publicación : 2007
Aparece en las colecciones: Artigo Publicado em Periódico (Química)

Ficheros en este ítem:
No hay ficheros asociados a este ítem.


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.