Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/6344
Tipo: Artigo de Periódico
Título: Statistical design-principal component analysis optimization of a multiple response procedure using cloud point extraction and simultaneous determination of metals by ICP OES
Título(s) alternativo(s): Analytica Chimica Acta
Autor(es): Bezerra, Marcos de Almeida
Bruns, Roy Edward
Ferreira, Sergio Luis Costa
Autor(es): Bezerra, Marcos de Almeida
Bruns, Roy Edward
Ferreira, Sergio Luis Costa
Abstract: A procedure has been developed for the simultaneous determination of traces amounts of Cd, Cr, Cu, Mn, Ni and Pb from saline oil-refinery effluents and digested vegetable samples using inductively coupled plasma optical emission spectrometry (ICP OES). The procedure is based on cloud point extraction (CPE) of these metals as 2-(bromo-2-pyridylazo)-5-diethyl-amino-phenol (Br-PADAP) complexes into a micellar phase of octylphenoxypolyethoxyethanol (Triton X-114). Optimization of the procedure was performed by response surface methodology (RSM) using a Doehlert design. Principal components (PC) were used to simplify the multiple response analysis. A response surface for the first PC score is useful in determining the optimum conditions for the Cd, Cr, Cu, Mn and Pb determinations whereas the second PC is highly correlated with the Ni response. Improvement factors of 22, 36, 46, 25, 65 and 39, along with limits of detection (3σB) of 0.081, 0.79, 0.38, 0.83, 0.28 and 0.69 μg L−1, and precision expressed as relative standard deviation (%R.S.D., n = 8, 20.0 μg L−1) of 1.5, 2.2, 3.5, 2.6, 2.5 and 2.5 were achieved for Cd, Cr, Cu, Mn, Ni and Pb, respectively. The accuracy was evaluated by spike tests in oil-refinery effluent samples and analysis of a vegetable certified reference material (NIST 1571, orchard leaves). Results found were in agreement with certified values.
Palavras-chave: Cloud point extraction
Doehlert design
Simultaneous determination in inductively coupled plasma optical emission spectrometry (ICP OES)
Principal component analysis
Response surface analysis
Editora / Evento / Instituição: Analytica Chimica Acta
URI: http://www.repositorio.ufba.br/ri/handle/ri/6344
Data do documento: 2006
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DD.pdf_5407,78 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.