Título: Sequential determination of Cd and Cr in biomass samples and their ashes using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
Título(s) alternativo(s): Talanta
Autor(es): Duarte, Alvaro T.
Dessuy, Morgana B.
Vale, Maria Goreti R.
Welz, Bernhard
Andrade, Jailson Bittencourt de
Autor(es): Duarte, Alvaro T.
Dessuy, Morgana B.
Vale, Maria Goreti R.
Welz, Bernhard
Andrade, Jailson Bittencourt de
Abstract: High-resolution continuum source graphite furnace atomic absorption spectrometry, because of the use of only one radiation source for all elements, offers the possibility of sequential determination of two or more elements from the same sample aliquot if their volatilities are significantly different. Cd and Cr were determined sequentially in samples of biomass and biomass ashes employing direct solid sample analysis. The use of a chemical modifier was found to be not necessary, and calibration could be carried out using aqueous standard solutions. A pyrolysis temperature of 400 °C and an atomization temperature of 1500 °C were used for the determination of Cd; no losses of Cr were observed at this temperature. After the atomization of Cd the wavelength was changed and Cr atomized at 2600 °C. The limits of detection (LOD) and quantification (LOQ) were 1.1 μg kg−1 and 3.7 μg kg−1, respectively, for Cd and 21 μg kg−1 and 70 μg kg−1, respectively, for Cr using the most sensitive line at 357.869 nm, or 90 μg kg−1 and 300 μg kg−1, respectively, using the less sensitive line at 428.972 nm. The precision, expressed as relative standard deviation was around 10%, which is typical for direct solid sample analysis. The values found for Cd in biomass samples were between <1.1 µg kg−1 and 789 µg kg−1, whereas those for Cr were between 7.9 mg kg−1 and 89 mg kg−1; the values found in the ashes were significantly lower for Cd, between <1.1 µg kg−1 and 6.3 µg kg−1, whereas the trend was not so clear for Cr, where the values were between 3.4 mg kg−1 and 28 mg kg−1.
Palavras-chave: High-resolution continuum source AAS
Direct solid sample analysis
Sequential determination of two elements from the same sample aliquot
Cd and Cr in biomass and ash
Tipo de Acesso: Acesso Aberto
URI: http://repositorio.ufba.br/ri/handle/ri/16532
Data do documento: 2013
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Alvaro T. Duarte.pdf943,18 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.